DeDietrich C 330 Series Installation, User And Service Manual page 26

High-efficiency floor-standing boiler
Table of Contents

Advertisement

5 Before installation
Fig.10
Position of the control panel
Fig.11
Position of the adjustment bolts
663
21,5
55
55
55
55
87,5
531
26
AD-0000514-02
663
21,5
55
55
55
55
531
87,5
AD-0000510-01
Danger
It is forbidden to store, even temporarily, combustible products
and substances in or near the boiler.
Caution
The boiler must be installed in a frost-free area.
An earthed electrical connection must be available close to the
boiler.
A connection to the drain must be present for the condensate
drain close to the boiler.
The boiler is not available with a choice between 'left-hand' and 'right-
hand' versions. The control panel is on the front as standard, but can
easily be rotated so that it is on the short side.
The adjustment bolts must be used to make the boiler level and to raise
the wheels off the floor. Turn the adjustment bolts outwards as soon as the
boiler is placed in the correct position. The figure shows the support
surface of the boiler (this is the position of the adjustment bolts).
Tab.15
Dimensions A (mm)
C 630 ECO
560
700
860
1000
1140
1300
A (mm)
723
723
723
1032
1032
1032
7600532 - v.11 - 13122018