Operating Voltage

By default, the router is configured to enter Standby mode at 9 V. If you want to operate
the router at less than 9 volts, power it on using at least 9 V, launch ACEmanager, go to
Services > Power Management and adjust the Standby mode settings.
The maximum ripple voltage to guarantee analog input accuracy must be 100 mVpp.

Power Specifications

Table C-1: Power Supply Specifications
Pin
Name
1
VCC
Table C-2: Ignition Sense Specifications
Pin
Name
3
IS
(Input only)
Note: If you do not connect this pin to the ignition, you MUST connect it to the positive terminal of your power supply or
battery. The device looks for a qualified voltage on this pin as part of the power up sequence. If it doesn't see it, the
device will not turn on. If you are using a Sierra Wireless AC power adapter, the connection is inside the cable.

GNSS Technology

Satellite channels
Constellations
Protocol
Acquisition time (Time
Sensitivity
Rev. 1 June 2019
Specification
Voltage range
Input Impedance
(Typ)
80 kΩ (minimum)
to first fix)
Parameter
VCC
Specification
Input low state voltage
(maximum)
Input high state voltage
(minimum guaranteed)
Maximum 48 tracking channels and 2 fast acquisition channels
GPS
Galileo
GLONASS
BeiDou
QZSS
NMEA 0183 V3.0
Hot start: 1 second
Cold start: 30 seconds
Indoor sensitivity (tracking mode): -162 dBm
46
Minimum
Maximum
7 V
Parameter
Minimum
V
IL
V
3.3 V
IH
36 V
Maximum
1.0 V
V
in