TECHNICAL DATA
Input (net)
Output (net)
SEDBUK Rating
Burner
Weight (empty)
Water Content
Flow & Return
Max. Operating Pressure (HTG)
Test Pressure
Starting Current
Running Current
Electrical Supply
Fuse
Maximum Pressure
Fuel
Hot Water Thermostat
High Limit Thermostat
Casing Finish
Thermal Insulation
Optional Extras
Model
Input
50,000
52,247 BTUs
60,000
62,781 BTUs
70,000
74,723 BTUs
Boiler shell and casings insulated with glass fibre
Output
(non condensing)
50,000 BTUs
60,051 BTUs
70,970 BTUs
74,723 BTU/h
70,970 BTU/h
A
See Burner Details Leaflet
91kg
16 litres
22mm Compression
3 bar (43.5 psi)
4.5 bar (65.3 psi)
3.5
0.77
230/240v – 50Hz 220W
Fused at 5 amp
3 bar
Kerosene 28s BS 2869 Class C2
Adjustable between 55°C and 80°C
Factory-set at 110°C (manual reset)
Stove enamel painted white
Trianco balanced flue kit range (page 19)
Output
Nozzle
(condensing)
50,784 BTUs
0.45 x 80ºEH
61,075 BTUs
0.60 x 80ºEH
72,676 BTUs
0.60 x 80ºEH
9
Pump
CO
2
Pressure
(%)
120 psi
11.8
95 psi
11.5
135 psi
11.4
Need help?