READ Function

Reads out the constants in batch from the Inverter and stores them in
EEPROM inside the Digital Operator. When the read-out is executed,
the previously stored constants data in the EEPROM are cleared and
replaced with the newly entered constants.
Example: Storing Constants from Inverter in EEPROM in Operator.
Enable the setting of con-
stants n01 to n79.
Set Constant Read Pro-
hibited Selection (n77) to
*1
read-enabled.
Execute read-out (READ)
using the Constant Copy
Function Selection (n76).
86
Explanation
Press DSPL to light
[PRGM].
Press ENTER to display
the set value.
Change the set value to 4
by pressing the
key.
Press ENTER.
Change the constant No.
to n77 by pressing the
or
key.
Press ENTER to display
the set value.
Change the set value to 1
by pressing the
key.
Press ENTER.
Change the constant No.
by pressing the
key.
Press ENTER to display
the set value.
Change the set value to
rEd by pressing the
key.
Press ENTER.
Press DSPL or ENTER.
Operator Display
(May be a different constant No.)
(Lit)
(May be a different set value.)
(Flashes)
or
(Lit for one second.)
(The constant No. is displayed.)
(Lit)
(Flashes)
or
(Lit for one second.)
(The constant No. is displayed.)
or
(Lit)
(Lit)
or
(Flashes while executing the
read)
(End is displayed after the read
has been completed.)
(The constant No. is displayed.)