Inverter Capacity Display
The voltage class and maximum applicable motor capacity for which
constants are stored in the Digital Operator are displayed.
Example: Displaying Voltage Class and Maximum Applicable Motor
Capacity for Inverter whose Constants are in EEPROM in Operator
•
Enable the setting
for constants n01 to
n79.
•
Execute Inverter
Capacity Display
(vA) using the Con-
stant Copy Function
Selection (n76).
* The following figure shows the Inverter Capacity Display
b
2
4
90
Explanation
•
Press DSPL to light [PRGM].
•
Press ENTER to display the
set value.
•
Change the set value to 4 by
pressing the
•
Press ENTER.
•
Change the constant No. to
n76 by pressing the
key.
•
Press ENTER to display the
set value.
•
Change the set value to vA fy
by pressing the
•
Press ENTER.
•
Press DSPL or ENTER.
Voltage Class
Single-phase 200 V
Three-phase 200 V
Three-phase 400 V
No.
0.1
0.2
0.4
0.7
1.5
2.2
3.0
3.7
(May be a different constant No.)
(Lit)
(May be a different constant No.)
(Flashes)
or
key.
(Lit for one second.)
↓
or
(Lit)
or
key.
Max. Applicable Motor Capacity
0.1 kW
0.2 kW
0.4 kW
0.75 kW
1.5 kW
2.2 kW
3.0 kW
3.7 kW
Operator Display
(The constant No. is displayed.)
(Lit)
(Lit) (For 20P7)*
(The constant No. is displayed.)