Inverter Capacity Display

The voltage class and maximum applicable motor capacity for which
constants are stored in the Digital Operator are displayed.
Example: Displaying Voltage Class and Maximum Applicable Motor
Capacity for Inverter whose Constants are in EEPROM in Operator
Enable the setting
for constants n01 to
n79.
Execute Inverter
Capacity Display
(vA) using the Con-
stant Copy Function
Selection (n76).
* The following figure shows the Inverter Capacity Display
b
2
4
90
Explanation
Press DSPL to light [PRGM].
Press ENTER to display the
set value.
Change the set value to 4 by
pressing the
Press ENTER.
Change the constant No. to
n76 by pressing the
key.
Press ENTER to display the
set value.
Change the set value to vA fy
by pressing the
Press ENTER.
Press DSPL or ENTER.
Voltage Class
Single-phase 200 V
Three-phase 200 V
Three-phase 400 V
No.
0.1
0.2
0.4
0.7
1.5
2.2
3.0
3.7
(May be a different constant No.)
(Lit)
(May be a different constant No.)
(Flashes)
or
key.
(Lit for one second.)
or
(Lit)
or
key.
Max. Applicable Motor Capacity
0.1 kW
0.2 kW
0.4 kW
0.75 kW
1.5 kW
2.2 kW
3.0 kW
3.7 kW
Operator Display
(The constant No. is displayed.)
(Lit)
(Lit) (For 20P7)*
(The constant No. is displayed.)