YASKAWA VS mini J7 Series Instruction Manual page 66

Compact general-purpose inverter
Hide thumbs Also See for VS mini J7 Series:
Table of Contents

Advertisement

The factory setting depends on the Inverter capacity (kVA).
Voltage
Capacity
Class (V)
(kW)
200 V
0.1
Single-
phase or
0.2
3-phase
0.4
0.75
1.5
2.2
3.7
400 V
0.2
3-phase
0.4
0.75
1.5
2.2
3.0
3.7
1. Reduce the continuous output current when changing the
NOTE
carrier frequency to 4 (10 kHz) for 200 V Class (1.5 kW
or more) and 400 V Class Inverters. Refer to the table
above for the reduced current.
Operation Condition
• Input power supply voltage:
• Ambient temperature:
Initial Setting
Setting
Carrier Fre-
quency (kHz)
4
10
4
10
4
10
4
10
3
7.5
3
7.5
3
7.5
3
7.5
3
7.5
3
7.5
3
7.5
3
7.5
3
7.5
3
7.5
3-phase 200 to 230 V (200 V Class)
Single-phase 200 to 240 V (200 V Class)
3-phase 380 to 460 V (400 V Class)
−10 to 50°C
(Protection structure: open chassis type IP20)
6. Programming Features
Maximum
Continuous
Output Cur-
rent (A)
0.8
1.6
3.0
5.0
8.0
11.0
17.5
1.2
1.8
3.4
4.8
5.5
7.2
8.6
Reduced
Current
(A)
-
7.0
10.0
16.5
1.0
1.6
3.0
4.0
4.8
6.3
7.6
65