Frequency
reference
FWD (REV) RUN/STOP
Multi-step speed ref. 1
(terminal S3)
Multi-step speed ref. 2
(terminal S4)
Multi-step speed ref. 3
(terminal S5)

Operating at Low Speed

By inputting a JOG command and then a FORWARD (REVERSE)
RUN command, operation is enabled at the jog frequency set in n29.
When multi-step speed references 1, 2, 3 or 4 are input simultaneously
with the JOG command, the JOG command has priority.
Constant No.
n29
n36 to n39
52
(n25) 45.0 Hz
(n24) 40.0 Hz
(n23) 35.0 Hz
(n22) 30.0 Hz
(n21) 25.0 Hz
Name
Jog Frequency
Jog References Set to 10 for any constant.
(n28) 60.0 Hz
(n27) 55.0 Hz
(n26) 50.0 Hz
Setting
Initial setting: 6.0 Hz