FBII XL-20 Hookup And Installation Instructions page 52

Hardwired/wireless system
Hide thumbs Also See for XL-20:
Table of Contents

Advertisement

Question 23, L1 & L2 - Keypad Fire Code
L1 - L2 is the Alarm code that will be transmitted upon activation of the Keypad Fire
condition (pressing the two Fire keys or the 7 & 9 keys on the keypad). This code can
vary from any of the zones that are programmed as Fire.
Question 23, L3 & L4 - Keypad Auxiliary Code
L3 - L4 is the code transmitted to the CS for Keypad Aux. condition (pressing the two
Aux keys or 1 & 3 from the keypad).
NOTE: These keypad emergency conditions are optional and can be enabled within question
#05 of the programming sequence. If either or both of these transmissions are not desired,
program their respective locations as "AA."
QUESTION 24
CS CODES RF LOW BATTERY & SUPERVISION
There are 4 locations (L1-L4) in this question:
Question 24, L1 - RF Low Battery Code
Question 24, L2 - RF Low Battery Restore
Question 24, L3 - RF Supervisory
Question 24, L4 - RF Supervisory Restore
QUESTION 25
CS CODES BELL SUPERVISION & TAMPER
There are 4 locations (L1-L4) in this question:
Question 25, L1 & L2 - Bell Supervision Code
Question 25, L3 - RF Tamper Code
Question 25, L4 - RF Tamper Reset
QUESTION 26
RF ZONES
There are 4 locations (L1-L4) in this question:
Question 26, L1 - RF Zones 5-8
Question 26, L2 - RF Zones 1-4
L1 - RF Zones 5-8
RF ZONES
Digit
8
0
1
2
3
4
5
6
7
'
8
'
9
'
A
'
B
'
C
'
D
'
E
'
F
7
6
5
None
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
Section 9 - System Programming
DEFAULT = AAAA
DEFAULT = AAAA
DEFAULT = 00A0
L2 - RF Zones 1-4
RF ZONES
Digit
4
3
0
None (Zones 1-4 Are Hardwired)
1
2
3
'
4
'
5
'
6
'
7
'
8
'
9
'
A
'
B
'
'
C
'
'
D
'
'
E
'
'
F
Default = AA
Default = AA
Default = A
Default = A
Default = A
Default = A
Default = AA
Default = A
Default = A
Default = 0
Default = 0
2
1
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
9–19