XL-20 Hookup and Installation Instructions
faulted, an Exit Error will occur at the end of the exit time unless the faulted zones become
restored.
DIALING PULSE TYPE - Specifies how this control will perform pulse dialing (U.S. Pulse
or European Pulse) when CS transmissions are enabled.
U L
European Pulse has not been tested for UL installations.
AUTO STAY - If enabled, the system will always be armed in the STAY mode with all
interior zones enabled with the Stay option bypassed. The Stay zones will become armed only
if someone exits through a delay zone during the exit delay period.
POOL ZONE - If enabled, activates the Pool Zone (zone 4) when the system is disarmed.
When the system is armed, zone 4 acts like a normal delay zone and depressing one of the
Pool Zone momentary switches will start the entry delay time.
Question 05 L3
Quick Commands & Quick Exit
Enter the digit from the table below in location L2. NOTE: The checkmarks highlight which
options are selected.
QUICK FORCED ARMING - Specifies whether Quick Forced Arming (#2) will be
permitted. If chosen, Quick Forced Arming will arm the system bypassing any faulted zones.
Openings/Closings will report User no. 8 to the CS if enabled.
U L
For UL installations do not select this option.
QUICK ARMING - Specifies whether Quick Arming (#1) will be permitted. If chosen, Quick
Arming will arm the system ONLY if the system is READY. Openings/Closings will report
User no. 8 to the CS if enabled.
QUICK BYPASS - Specifies whether bypassing a zone without a User code is permitted.
9–6
QUICK COMMANDS
Q U I C K
Digit
F O R C E D
ARMING
0
'
1
2
'
3
4
'
5
6
'
7
8
'
9
A
'
B
C
'
D
E
'
F
Q U I C K
Q U I C K
ARMING
BYPASS
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'