FBII XL-20 Hookup And Installation Instructions page 40

Hardwired/wireless system
Hide thumbs Also See for XL-20:
Table of Contents

Advertisement

QUICK EXIT - If enabled, this feature allows the user to exit without having to disarm,
then arm, the system. It is activated by pressing the STAY key while the system is armed
and not in entry delay. This will start exit time, cause the keypad to beep once and allow the
user to exit without disarming the system. The system will return to its last armed state
after exit time has expired.
Question 05, L4
Rest. Foll. Loop, User On-line, CS Test K.P. Ringback & User 5 Arm
Enter the digit from the table below in location L4. NOTE: The checkmarks highlight which
options are selected.
RESTORE
Digit
AFTER BELL
'
0
1
'
2
3
'
4
5
'
6
7
'
8
9
'
A
B
'
C
D
'
E
F
RESTORE AFTER BELL - Restores will be transmitted after the loop has returned to
normal after bell cutoff, or upon system disarming, regardless of the loop status.
RESTORE FOLLOWS LOOP - Restores will be transmitted immediately upon zone
restoral while the system is armed, or upon system disarm, regardless of the loop status.
USER ON-LINE & CHIME TOGGLE ENABLE - Enables the end user command (#9) for
the on-line download. This command instructs an end user on how to initiate an on-line
download, possibly preventing a service call. This option also enables the user chime toggle
(#6).
CS TEST RING BACK - Normally, after a CS Test report has reached the central station, a
sounder ringback can be heard from the keypad indicating a successful communication to the
CS. If SILENT is selected, then NO sounder ringback will be heard from the keypad after
a CS Test report. If AUDIBLE is selected, then a sounder ringback will be heard from the
keypad after a CS Test report.
Audible ringback automatically occurs on all alarms except silent alarms, regardless of the setting
of this option.
USER 5 ARMS ONLY - If selected, then User 5 will be used as an ARM-only code (Maid
code); it will not disarm the system.
QUESTION 06
SYSTEM TIMEOUTS
There are 4 locations (L1-L4) within this question, which defines various system timing
options, as follows:
RESTORE
USER
FOLLOWS
ON-LINE
LOOP
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
Section 9 - System Programming
CS TEST KEYPAD
RING BACK
SILENT
AUDIBLE
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
DEFAULT = 1000
Default = 4
USER 5
ARMS ONLY
'
'
'
'
'
'
'
'
9–7

Advertisement

Table of Contents
loading

Table of Contents