XL-20 Hookup and Installation Instructions
Question 06, L1
Entry Delay 1
Enter the desired entry delay time for zones 1-3. Refer to Exit/Entry Times below for valid
choices. If zones 1-3 are delay zones, they follow Entry Delay 1. For UL applications,
the maximum Entry Delay shall not exceed 45 seconds for household applications or 15
seconds for commercial burglary applications. NOTE: See programming question 07, location
1 for Entry Delay 2.
Question 06, L2
Exit Delay
Enter the desired exit time. NOTE: For UL applications, the maximum exit delay shall not
exceed 60 seconds.
Question 06 L3
Burglary Bell Cutoff
Enter the desired bell cutoff time on alarm conditions for burglary and panic in 3-minute
intervals (for example, 3 = 9 minutes). The valid range of input is 1 - F, with F indicating an
infinite burglary bell cutoff. For UL installations, the minimum bell cutoff shall be 15
minutes in commercial applications, or 6 minutes in household burglary applications.
9–8
Digit
ENTRY TIMEOUTS
0
1 SECOND
1
5 SECONDS
2
10 SECONDS
3
15 SECONDS
4
20 SECONDS
5
25 SECONDS
6
30 SECONDS
7
35 SECONDS
8
40 SECONDS
9
45 SECONDS
A
50 SECONDS
B
55 SECONDS
C
1 MINUTE
D
1 MINUTE 5 SECONDS
E
1 MINUTE 10 SECONDS
F
3 MINUTES
Digit
EXIT TIMEOUTS
0
1 SECOND
1
10 SECONDS
2
20 SECONDS
3
30 SECONDS
4
40 SECONDS
5
50 SECONDS
6
1 MINUTE
7
1 MINUTE 10 SECONDS
8
1 MINUTE 20 SECONDS
9
1 MINUTE 30 SECONDS
A
1 MINUTE 40 SECONDS
B
1 MINUTE 50 SECONDS
C
2 MINUTES
D
2 MINUTES 10 SECONDS
E
2 MINUTES 20 SECONDS
F
3 MINUTES
Default = 6
Default = 6
Default = 5