FBII XL-20 Hookup And Installation Instructions page 47

Hardwired/wireless system
Hide thumbs Also See for XL-20:
Table of Contents

Advertisement

XL-20 Hookup and Installation Instructions
system is not disarmed within the programmed entry time, an alarm will occur. The keypad
sounder annunciates steadily during entry time, unless there has been an alarm condition, in
which case it pulses. Delay zones activate instantly when the system is armed using the
STAY/INSTANT mode, if enabled. Delay zones employ the Exit Error Warning feature
described in the note below.
INTERIOR - All interior zones have exit delay time upon system arming. Furthermore, all
interior zones will have entry delay time if a delay zone is violated first. If this zone is
violated first, however, it will generate an immediate alarm. Interior zones are bypassed if
the system is armed in the STAY mode. Interior zones employ the Exit Error Warning
feature described in the note below.
PERIMETER - This zone type (sometimes known as INSTANT) will generate an alarm
when violated while the system is armed.
EXIT ERROR WARNING - When a user code is entered to arm the system, the
burglary bell and keypad sounder will be turned on during the entry and exit time.
Burglary Zone Options
RESTORE - This option is selected for all burglary zones by enabling the Restore report
code (question 19, location 2) and enabling zone Restores in question 04, location 4. The
programmed Restore code will be reported upon bell cutoff, assuming the loop is restored,
unless Restore Follows Loop is selected in question 05, location 4. The Restore code will also
be reported if the system is disarmed during an alarm. NOTE: Restore is not selectable by
zone.
BYPASS IN STAY - This option allows zones to be bypassed when the system is armed in
the STAY mode.
CHIME - If this option is selected, the keypad sounder will annunciate for 1 second when
this zone is violated in the disarmed mode.
DIALER DELAY - If this option is selected, the system will allow a 15-second delay (or 30
seconds, as per question 04, location 4) before dialing, allowing the end user to ABORT the
transmission. If this option is not selected, any alarm condition will result in an immediate
transmission that cannot be aborted.
U L
For UL installations dialer delay may not be used.
DAY FEATURE - If a zone with this option is violated while the system is DISARMED, the
keypad sounder and zone LED will pulse for as long as the violation remains. In addition, if
the violation remains for 15 seconds, the SYSTEM TROUBLE CODE will be transmitted to
the central station. THE SOUNDER CAN BE SILENCED through entry of any valid user
code. While the system is armed, a DAY zone will act as an alarm when violated.
Zones 1-8 can be programmed for any one of the following 24-hour zone types:
9–14
L1L2
24 HR.
Digits
ALARM
'
81
82
84
'
89
8A
24-HOUR ZONES
ZONE TYPE
24 HR.
FIRE
TROUBLE
'
'
'
ZONE OPTIONS
AUDIBLE
SILENT
'
'
ALWAYS AUDIBLE
'
'