AC LOSS SOUNDER - Choosing this option causes the keypad sounder to pulse after a 15
minute long AC power loss.
EUROPEAN RING DETECT - Select this option only if the system uses a European
Telephone System. This option changes the ring detection frequency used for Automatic
Answer mode for remote (downloading) purposes only, according to the programmed ring
count (see programming question 07, location 2). If you choose this option, the ring detection
frequency range is 10 - 90Hz. If not, the frequency range is 16 - 90Hz.
QUESTION 08
BELL RING ON CANCEL, ARM/DISARM BELL TEST,
BELL TEST CHIRP
There are 4 locations (L1-L4) within this question, which defines various system timing
options as follows:
Question 08, L1
Bell Ring on Cancel, Arm Bell Test, Disarm Bell Test & Bell Test Chirp
BELL RING
Digit
ON CANCEL
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
BELL RING ON CANCEL - Choosing this option causes the bell to ring for 1 second after
kissoff of cancel to central station.
ARMING BELL TEST - Choosing this option causes a 1-second bell when system starts
DISARM BELL TEST - Choosing this option causes a 1-second bell when system disarms
BELL TEST CHIRP - This option is for use with sirens that respond quickly to an output.
It shortens (to 100ms) both the Arming Bell Test and Disarm Bell Test.
Question 08, L2
Instant Led Pulse, Open/Close Users 4/12, Temporal Bell
Digit
INSTANT LED PULSE
0
1
2
3
8
9
A
B
ARM BELL
TEST
NONE
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
O/C USERS 4/12
'
'
'
'
Section 9 - System Programming
DISARM
BELL TEST
BELL TEST
CHIRP
'
'
'
'
'
'
'
'
TEMPORAL BELL
'
'
'
'
'
'
'
'
DEFAULT = 0000
Default = 0
'
'
'
'
'
'
'
'
Default = 0