14 Accessories

Ball guards

Ball protection grids acc.18032-3 for using heaters in
sport halls [grid 40x40mm].
Delivery scope
Mounting set complete for each type of heater
existing of:
infra/calorSchwank D shape U
Ball protection grid L=1443mm
Ball protection grid L=1843mm
Ball protection grid L=2203mm
Ball protection grid L=2963mm
Protection grid burner top
Front protection cover burner
Protection grid burner end side
End bracket with stud bolts M8
Holding bracket [1x infra D +1x calor D]
Angled bracket with stud bolt M8
Clamp
Set fixing material
Article number
Tab. 11: Overview delivery scope ball guards
Assembling instruction
[Description for heater infra/calorSchwank D 30 U,
other types similar]
1. Mounting heater as described in chapter 9,
page 24-29].
Note the required sideways slope of the heater of
20mm in ball protection grid application [Fig. 48].
2. Fix end bracket at inner side of turnaround box,
open and close again 4 nuts M8 [Fig. 50]
3. Fix two angle brackets at each tube hanger
[screws M8 x 60, nuts] [Fig. 51]
Screw on angled brackets at the inner holes of
suspension bracket
NOTE 50-60kW: Screws to fixing suspension bracket
bars must be inserted from below.
4. Holding bracket put loose on the first reflector [view
from burner unit] and screw together with two
angle brackets [screws M8 x 60, nuts], holding
bracket remain axially movable
54
15U
20U
30U
2x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
4x
4x
6x
6x
1x
1x
12670800
12674350
12670810
NOTE: Use the right holding bracket –
difference infraSchwank D or calorSchwank D
– both in the delivery scope [Fig. 52]!
5.
At all junctions ball protection segment to the
angle brackets the grid edges must be cut
free to ensure a gap-free fitting of the ball
protection segments grid to the reflector.
6.
Assembling segments ball protection grids
starts on the turnaround box [last suspension
bracket for shape L]. Put first segment ball
protection grid L=2963 mm from below on
end bracket and angle brackets of the next
suspension bracket – Put clamps on stud
bolts M8 and mount with self-locking nuts
Mount clamp loose on one stud bolt of angle
bracket for further assembling next
protection grid [Fig. 53].
7.
Put next segment ball protection grid
L= 1843 mm from below on angle brackets
and mount clamp with self-locking nuts M8,
clamp and angle bracket connect two
segments ball protection grid to each other.
Mount clamp loose on one stud bolt of angle
40U
50U
2x
2x
2x
1x
2x
3x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
6x
8x
10x
8x
10x
12x
1x
1x
1x
12670820
12670830
60U
1x
2x
3x
1x
1x
1x
1x
1x
12x
14x
1x
12674360