Carrier Controller Display; Carrier Controller Display User Interface - Carrier AquaForce B Series Controls, Start-Up, Operation, Service And Troubleshooting Instructions

Variable speed air-cooled liquid chillers with greenspeed intelligence and carrier controller
Table of Contents

Advertisement

UNIT
Typical Field Connections Wiring Schematic
30XV325
Typical Field Connections Wiring Schematic
30XV350
Typical Field Connections Wiring Schematic
30XV400
Typical Field Connections Wiring Schematic
30XV450
Typical Field Connections Wiring Schematic
30XV500

Carrier Controller Display

The Carrier Controller module is the HMI (Human Machine
Interface) and core of the control system. It contains the major
portion of operating software and controls the operation of the
machine. See "Web and Network Interface" on page 13.
The Carrier Controller module continuously monitors input/
output channel information received from the SIOB (Standard
Input/Output Board) and AUX (Auxiliary) board. The Carrier
Controller module receives inputs from status and feedback
switches, pressure transducers and thermistors. The Carrier
Controller module, through the communications bus, also con-
trols outputs on the SIOB and AUX boards. All inputs and out-
puts that control the chiller are located on other boards. Infor-
mation is transmitted between modules via a 3-wire communi-
cation bus or LEN (Local Equipment Network).
The CCN bus is also supported.
Connections to both LEN and CCN buses are made at terminal
board TB3 located within the control box enclosure to the left
of the Carrier Controller display. See Fig. 1 and 2 for compo-
nent layout showing the display with field connections.
Table 2 — Control and Power Drawings (cont)
DESCRIPTION
Power Wiring Schematic (Std)
Power Wiring Schematic (Mid)
Power Wiring Schematic (High)
Communication Wiring
Control Wiring Schematics
Component Arrangement
Power Wiring Schematic (Std)
Power Wiring Schematic (Mid)
Power Wiring Schematic (High)
Communication Wiring
Control Wiring Schematics
Component Arrangement
Power Wiring Schematic (Std)
Power Wiring Schematic (Mid)
Power Wiring Schematic (High)
Communication Wiring
Control Wiring Schematics
Component Arrangement
Power Wiring Schematic (Std)
Power Wiring Schematic (Mid)
Power Wiring Schematic (High)
Communication Wiring
Control Wiring Schematics
Component Arrangement
Power Wiring Schematic (Std)
Power Wiring Schematic (Mid)
Communication Wiring
Control Wiring Schematics
Component Arrangement
Fig. 90, pages 227-228
Fig. 92, pages 230-231
Fig. 98, page 238-239
Fig. 98, page 238-239
Fig. 99, page 240
Fig. 100-101, pages 241-243
Fig. 103, pages 246-247
Fig. 90, pages 227-228
Fig. 93, page 232-233
Fig. 94, page 234
Fig. 94, page 234
Fig. 99, page 240
Fig. 100, 102, pages 241, 244-245
Fig. 104, page 248
Fig. 90, pages 227-228
Fig. 93, page 232-233
Fig. 94, page 234
Fig. 94, page 234
Fig. 99, page 240
Fig. 100, 102, pages 241, 244-245
Fig. 104, page 248
Fig. 90, pages 227-228
Fig. 93, page 232-233
Fig. 94, page 234
Fig. 94, page 234
Fig. 99, page 240
Fig. 100, 102, pages 241, 244-245
Fig. 104, page 248
Fig. 90, pages 227-228
Fig. 93, page 232-233
Fig. 94, page 234
Fig. 99, page 240
Fig. 100, 102, pages 241, 244-245
Fig. 104, page 248

Carrier Controller Display User Interface

The Carrier Controller display is the standard user interface on all
30XV chillers with Greenspeed
cludes a large 7-in. LCD (Liquid Crystal Display) touch screen for
display and user configuration. A stylus is recommended for use
on the touch screen. The stylus is included with the unit.
WELCOME SCREEN
The Welcome screen is the first screen shown after Carrier
Controller is powered on. See Fig. 3.
The Welcome Screen will automatically change to the Home
Screen when the controller has completed initialization.
HOME SCREEN
The Home screen provides an overview of system controls, al-
lowing the user to monitor the vapor-refrigeration cycle. The
screen indicates the current status of the unit, giving informa-
tion on the unit capacity, refrigerant conditions, occupied sta-
tus, capacity limit, compressor A and B status, the active set
point, and other information. See Fig. 4 and 5.
5
LOCATION
®
Intelligence. The display in-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading