Move the SEPARATING KNIFE PLATE fully to the right
5
with your hand and check and make sure that the clearance
with the STOPPER is 0.5—1.0 mm.
If the clearance measured at 4 is out of 0.5—1.0 mm, press
6
[MENU] key and enter the KNIFE ADJUST MODE.
In case the clearance is more than 1.0 mm, change the values
7
to the minus with [
] key.
In case it is less than 0.5 mm, change the value to the plus with
[
] key.
Then, press [ENTER] key to save the settings.
Re-check and make sure that the clearance is 0.5—1.0 mm by
8
carrying out the KNIFE TEST MODE.
If not, re-adjust the position.
STOPPER
0.5—1.0 mm
[MENU] key
[TEST] key
[ENTER] key
KNIFE TEST
4 Adjustment
SEPARATING
KNIFE PLATE
4
49