3 Replacement of Main Parts
Remove the CARRIAGE BOARD STAY and detach the
4
TOOL CARRIAGE from the GUIDE RAIL.
3
Remove the 2 screws shown in the figure and remove the
5
SEPARATING KNIFE from TOOL CARRIAGE.
Remove the PINCH ROLL SENSOR.
6
It is necessary to prepare a soldering iron or pin-
disconnector to remove PINCH ROLL SENSOR.
Fix the SEPARATING KNIFE to the new TOOL
7
CARRIAGE by pushing the SEPARATING KNIFE STAY
against the groove part of CARRIAGE BASE as shown in the
figure.
18
TOOL
CARRIAGE
SEPARATING KNIFE
PINCH ROLL SENSOR
SEPARATING KNIFE
GROOVE