4 Adjustment
Press the [ENTER] key and move the pen UP.
9
4
Change the "Force" to 200g with [
10
Then, press the [ENTER] key to move the pen DOWN.
Adjust VR2 on the MAIN BOARD so that the pressure would
11
be 199—200gf when pen tip leaves the BED.
Change the pressure to "20g" again and make sure the
12
pressure is 26—30gf.
If not, re-adjust it.
36
] and [
] keys.
[ENTER] key
[ ]&[ ]keys
[ENTER]key
ST-002
BED
ST-012
BED
VR2
MAIN BOARD