Table 17. Symptom-to-FRU index (continued)
Problem
indicator
Component
All green LEDs
All CRUs
are off
Amber LED is
Drive CRUs
flashing
Amber Conflict ID
Rear panel
is lit
One or more
Drive CRUs
green LEDs are
on
One or more
Drive CRUs
green LEDs are
blinking slowly
One or more
Power supply
green LEDs are
CRUs
off
All drive CRUs
Several CRUs
Front panel
Possible cause
Possible solutions
Subsystem power is
Check that all storage expansion
off
enclosure power cables are
plugged in and the power
switches are on. If applicable,
check that the main circuit
breakers for the rack are
powered on.
AC power failure
Check the main circuit breaker
and ac outlet.
Power-supply failure Replace the power supply.
Midplane failure
Contact an IBM technical-support
representative to service the
storage expansion enclosure.
Drive rebuild or
No corrective action needed.
identity is in process
The same enclosure
Using the x1 digit only, set the
ID is being shared
enclosure ID for each storage
by several storage
expansion enclosure in a drive
expansion
loop to a unique number 00 to
enclosures.
07.
DS4000 EXP710
Verify that the controller firmware
only: The DS4000
is at version 6.10.xx.xx or later
EXP710 is set up in
a configuration with
incorrect controller
firmware.
There is no activity
Note: This can indicate normal
to the drive.
activity.
Replace the SFP.
Power cable is
Make sure the power cable is
unplugged or
plugged in and the switches are
switches are turned
turned on.
off
Midplane failure
Replace the midplane (contact an
IBM technical-support
representative).
Hardware failure
Replace the affected CRUs. If
this does not correct the problem,
have the ESMs replaced,
followed by the midplane.
Contact an IBM technical-support
representative.
Power-supply
Make sure that the power cables
problem
are plugged in and that the
power supplies are turned on.
Hardware failure
If any other LEDs are lit, replace
the midplane. Contact an IBM
technical-support representative.
Chapter 4. Hardware maintenance
79