C4 User Manual
L120 Terminals – Internally fused source for all lock voltages.

Figure 20: Hall Lock Connector

2.13 Inspection Controls

ENABLE Button – Enables power to the direction commands for inspection operation. This
button must be pressed prior to issuing a direction to move on inspection.
INSPECTION Switch – Toggles between inspection and normal operation. When the MM input
signal is high and the switch is set to INSPECTION, the system is in Construction mode. If the
switch is set to NORMAL, the system is in test mode.
UP and DOWN Buttons – Moves the car either up or down on Inspection and Construction
mode.
CAR and HALL DOOR BYPASS Switches – Bypasses the hall locks and Gate switch only on CT
and IC inspection. These switches are used instead of jumpers to reduce the risk of accidentally
leaving a jumper still connected. These switches are not used in Construction mode and the
controller faults out if used any time outside CT or IC inspection.
August 15, 2019
© 2019 Smartrise Engineering, Inc. All Rights Reserved
Page 21