6.4.2 Oil Grade

Standard oils comply with DIN 51502 and DIN 51517 and are suitable for lubricating the gear unit. Food grade oils, which
comply with NSF H1, can be used.
The oil must permit low-friction, wear-free continuous operation. The damage load level on the FZG test as specified in
DIN 51354 should be in excess of load level 12, and the specific wear below 0.27 mg/kWh. The oil should protect against
corrosion and should not foam or attack the interior paint, the rolling contact bearings, gearwheels, and seals.
Do not mix different oil types, as this may impair the characteristics of the oil. A long service life is only ensured by the use
of oil listed in Table 6.4 or equivalent.
If the OneGearDrive is stored for a long period before installation, refer to chapter 8.2 Storage.
6
6
Only the following wear-protecting EP gear oils fulfil the requirements for the specified maintenance intervals (see
chapter 6.4.1 Oil Changes):
Oil manufacturer
ARAL
BP
CASTROL
FUCHS
KLÜBER
MOBIL
SHELL
TEXACO
Table 6.4 Oil Grades
20
Operating Instructions
Standard oil
Synthetic oil
PGLP 220
Degol GS 220
Enersyn SP-XP 220
Alphasyn PG 220
OPTIFLEX A 220
Renolin PG 220
Klübersynth GH 6-220
Glygoyle HE 220
Glygoyle 30
Omala S4 GX 220
Danfoss A/S © 06/2014 All rights reserved.
Food grade oil
NSF
USDA H1 oil
Eural Gear 220
OPTILEB GT 220
Cassida Fluid GL 220
Klüberoil 4UH1-220N
SHC Cibus 220
NEVASTANE SL220