GENERAL DATA
Model
Power supply
Noise level (sound pressure) (*1)
Noise level (sound power)
Air flow
Cabinet colour
Dimensions (H x W x D)
Net weight
Gross weight
Piping diameter (liquid / gas)
Minimum piping length
Maximum chargeless piping length
Maximum piping length
(additional refrigerant charge needed)
Height difference between OU and IU
(higher OU / lower OU)
Working range (cooling // heating // DHW)
Refrigerant
Refrigerant charge before shipment
Compressor type
(*) Need to be calculated
Blank data: To be informed later.
35
PMML0335A rev.1 - 04/2016
-
dB(A)
(*1)
dB(A)
(*2)
dB(A)
m
/min
3
-
mm
kg
kg
mm (inch)
m
m
m (g/m)
m
ºC (DB)
-
kg
-
RAS-8WHNPE
3N~ 400V 50Hz
73
71
127
Natural grey (1.0Y 8.5/0.5)
1380 x 950 x 370
137
152
Ø9.52 (3/8) / Ø25.4 (1")
15
70(*)
30 / 20
10~46 // -25~25 / -25~35
R410A
5.0
Scroll DC Inverter driven
RAS-10WHNPE
74
72
134
139
154
Ø12.70 (1/2) / Ø25.4 (1")
5
5.3