UNIT CONTROLLER

Auxiliary Sensors
REF
Access
Description
Taux1
Sensor 1
Taux2
Sensor 2
Taux3
Sensor 3
Sensors range visualization and constraints table:
Value
0
Disabled
1
Two3
2
Swimming Pool
3
Solar Panel Sensor
4
C1& C2 Ambient
5
C1 Ambient
6
C2 Ambient
7
Outdoor Sensor (NTC)
?
N O T E
These options cannot be repeated.
(*) The sensor 1 is forced to Two3 in case of Boiler installed and also in case of Heater installed for YUTAKI S80 or M.

8.6.3 Controller Settings

"Controller settings" contains different configuration options for the control. Those options are explained in the following items.

Controller Options

Room Names
Date and Time
Screen Settings
Language selection
REF
Access
-
Controller Options
-

Room Name

-
Date and Time
-
Screen settings
currentLanguage
Language selection
?
N O T E
(*1): Special screen.
161
PMML0335A rev.1 - 04/2016
Default Value
Auxiliary Sensors
Two3 (if Boiler)
Swimming pool (if SWP existing)
Outdoor Sensor
Available at
1(*)
2
3
O
O
O
Always
O
X
X
Always (*)
X
O
X
Available if Status (SWP) ("Status" of Swimming pool) is "Enabled".
Available if Solar combination (SOLStSet) ("Status" of Solar combination in
O
O
O
Complementary Heating menu) is set as "Total control".
Available if some of the Water Calculation modes (Water calculation mode for circuit
1 heating (C1WC) or Water calculation mode for circuit 1 cooling (CC1WC) or Water
O
O
O
calculation mode for circuit 2 heating (C2WC) or Water calculation mode for circuit
2 cooling (CC2WC)) are not set as "Disabled". It is not shown if C1 Ambient or C2
Ambient are configured.
Available if Water Calculation modes for circuit 1 (Water calculation mode for circuit 1
O
O
O
heating (C1WC) for heating or Water calculation mode for circuit 1 cooling (CC1WC)
for cooling) are not set as "Disabled". It is not shown if C1& C2 Ambient is configured.
Available if Water Calculation modes for circuit 2 (Water calculation mode for circuit 2
O
O
O
heating (C2WC) for heating or Water calculation mode for circuit 2 cooling (CC2WC)
for cooling) are not set as "Disabled". It is not shown if C1& C2 Ambient is configured.
O
O
O
Always
Description
Controller settings
Range
*See "Inputs range
visualization and
constraints table" below
Constraints
Visibility
Default
Range
Value
-
-
-
-
-
-
-
English
-
Steps Units
Application
S
SC S80 M
-
-
-
-
-
-
Steps Units
Application
S
SC S80 M
-
-
-
-
-
-
-
-
-
-
Notes
Notes
-
(*1)
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yutaki m seriesYutaki s80 seriesYutaki s combi seriesYutaki ras-2whvnpYutaki s seriesYutaki ras-3whvnp ... Show all

Table of Contents