UNIT CONTROLLER
Holiday Mode
REF
Access
absentYear
Year
absentMonth
Month
absentDay
Day
absentTime
Returning time
absentSetting
Setting Temperature
-
Start holiday mode
-
Stop holiday mode
?
N O T E
•
(*1): If "Holiday mode" is not operating.
•
(*2): If "Holiday mode" is operating.
Air Eco Offset
REF
Access
c1RTEcoOffset
Circuit 1
C2RTEcoOffset
Circuit 2
?
N O T E
•
(*1): If Controlled circuits (LCDL)= "C1" or "C1+C2".
•
(*2): If Controlled circuits (LCDL)= "Room C2" or "C1+C2".
Room Thermostats
Available if Controller type (LCDM)= "Unit" or "Unit + Room" .
•
Thermostats Type
(*1)
•
Compensation Factors
•
Room Temp Demand OFF
•
Check RT Address
(*3)
•
Detected Circuits
(*3)
•
Thermostat 1
(*4)
•
Thermostat 2
(*4)
?
N O T E
•
(*1):Visible only if Controller type (LCDM)= "Unit". Wireless not available only if Controller type (LCDM)= "Unit", If "Unit+Room" forced to wired.
•
(*2): If Water calculation modes (Water calculation mode for circuit 1 heating (C1WC)) or (Water calculation mode for circuit 1 cooling (CC1WC)) or
(Water calculation mode for circuit 2 heating (C2WC)) or (Water calculation mode for circuit 2 cooling (CC2WC)) as not "Disabled" and (Thermostat
type (RTType)= "Wireless" or "Wired" or Central mode (COT)= "Air" or "Full").
•
(*3): If Thermostat type (RTType)= "Wired" and Controller type (LCDM)= "Unit" or "Unit + Room".
•
(*4): If Controller type (LCDM)= "Unit" and Thermostat type (RTType)= "Wireless".
137
PMML0335A rev.1 - 04/2016
Description
Holiday Mode
Description
Air Eco Offset
(*2)
(*2)
Default
Range
Value
2015
-
1
1-12
1
1-31
0:00
0:00 ~23:50
21
5 - 35
No
No/Yes
No
No/Yes
Default
Range
Value
3
1-10
3
1-10
Steps
Units
Application
S
SC S80 M
-
-
○
○
○
1
Months
○
○
○
1
Days
○
○
○
00:10
Min.
○
○
○
1
ºC
○
○
○
-
-
○
○
○
-
-
○
○
○
Steps
Units
Application
S
SC S80 M
1
-
○
○
○
1
-
○
○
○
Notes
○
-
○
-
○
-
○
-
○
-
○
(*1)
○
(*2)
Notes
○
(*1)
○
(*2)