Download Print this page
Hitachi YUTAKI RAS-4WHVNPE Instruction Manual

Hitachi YUTAKI RAS-4WHVNPE Instruction Manual

Outdoor unit cooling & heating
Hide thumbs Also See for YUTAKI RAS-4WHVNPE:

Advertisement

Quick Links

INSTRUCTION
MANUAL
YUTAKI SERIES
OUTDOOR UNIT
MODELS
RAS-(4-10)WH(V)NPE
EN
INSTRUCTION MANUAL
ES
MANUAL DE INSTRUCCIONES
DE
BEDIENUNGSANLEITUNG
FR
MANUEL D'INSTRUCTIONS
IT
MANUALE DI ISTRUZIONI
PT
MANUAL DE INSTRUÇÕES
DA
BRUGSANVISNING
NL
HANDLEIDING
SV
INSTRUKTIONSHANDBOK
EL
ΕΓΧΕΙΡΙ∆ΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
PMML0372B rev.5 - 01/2021
BG
РЪКОВОДСТВО С УКАЗАНИЯ
CS
NÁVOD K POUŽITÍ
ET
KASUTUSJUHEND
HU
HASZNÁLATI ÚTMUTATÓ
LV
INSTRUKCIJU ROKASGRĀMATA
LT
NAUDOJIMO VADOVAS
PL
INSTRUKCJA OBSŁUGI
RO
MANUAL DE INSTRUCȚIUNI
RU
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
SK
NÁVOD NA POUŽITIE
UK
ПОСІБНИК З ЕКСПЛУАТАЦІЇ

Advertisement

loading

Summary of Contents for Hitachi YUTAKI RAS-4WHVNPE

  • Page 1 – INSTRUCTION MANUAL – YUTAKI SERIES OUTDOOR UNIT MODELS RAS-(4-10)WH(V)NPE INSTRUCTION MANUAL РЪКОВОДСТВО С УКАЗАНИЯ MANUAL DE INSTRUCCIONES NÁVOD K POUŽITÍ BEDIENUNGSANLEITUNG KASUTUSJUHEND MANUEL D'INSTRUCTIONS HASZNÁLATI ÚTMUTATÓ MANUALE DI ISTRUZIONI INSTRUKCIJU ROKASGRĀMATA MANUAL DE INSTRUÇÕES NAUDOJIMO VADOVAS BRUGSANVISNING INSTRUKCJA OBSŁUGI HANDLEIDING MANUAL DE INSTRUCȚIUNI INSTRUKTIONSHANDBOK...
  • Page 2 Specifikationerna i den här handboken kan ändras utan föregående meddelande för att Hitachi ska kunna leverera de senaste innovationerna till kunderna. Vi på Hitachi gör allt vi kan för att se till att alla specifikationer stämmer, men vi har ingen kontroll över tryckfel och kan därför inte hållas ansvariga för den typen av fel.
  • Page 3 Hitachi nie ponosi żadnej odpowiedzialności. Română Specificațiile din acest manual pot fi modificate fără notificare prealabilă, pentru ca Hitachi să poată pune la dispoziția clienților noștri ultimele inovații. Deși depunem toate eforturile pentru a ne asigura că toate specificațiile sunt corecte, erorile de tipărire depășesc controlul Hitachi;...
  • Page 4 C A U T I O N This product shall not be mixed with general house waste at the end of its life and it shall be retired according to the appropriated local or national regulations in a environmentally correct way. Due to the refrigerant, oil and other components contained in Air Conditioner, its dismantling must be done by a professional installer according to the applicable regulations.
  • Page 5 В Н И М А Н И Е В края на своя технологичен живот този продукт не бива да се изхвърля заедно с общите битови отпадъци и трябва да се третира съгласно приетите местни или национални подзаконови нормативни актове по правилен от гледна точка на опазване на...
  • Page 6 English Following Regulation EU No. 517/2014 on Certain Fluorinated Greenhouse gases, it is mandatory to fill in the label attached to the unit with the total amount of refrigerant charged on the installation. Do not vent R410A into the atmosphere: R410A are fluorinated greenhouse gases covered by the Kyoto protocol global warming potential (GWP) R410A = 2088.
  • Page 7 Български В съответствие с Регламент ЕС № 517/2014 за флуорсъдържащите парникови газове, е задължително да се попълни етикетът, закрепен за изделието, където да фигурира общото количество охлаждащ агент, зареден в инсталацията. Забранено е изпускането на R410A в атмосферата: R410A представлява флуорсъдържащи парникови газове, които са в обхвата на Протокола от Киото относно потенциалното...
  • Page 8 Protection Plastic Film Peel-off Paper Adhesive Surface Figure 1. F-Gas Label with Protection Plastic Film Figure 2. Protection Plastic Film English Instructions to fill in the “F-Gas Label”: 1.- Fill in the Label with indelible ink the refrigerant amounts:  - Factory Charge,  - Additional Charge,  - Total Charge &  t CO2 . 2.- Stick the Protection Plastic Film on the F-Gas Label (delivered in a plastic bag with the Manual).
  • Page 9 Български Указания за попълване на „Етикет за флуорсъдържащите газове”: 1.- Количествата охлаждащ агент попълнете в Етикета с неизтриваемо мастило:  - Заводско зареждане,  - Допълнително заредено количество,  - Общо заредено количество и  t CO2. 2.- Залепете защитния пластмасов филм върху Етикета за флуорсъдържащите газове (в пластмасов плик в комплект с Ръководството).
  • Page 10 Important note: Please, check, according to the model name, which is your heat pump type, how it is abbreviated and referred to in this instruction manual. This MODELS CODIFICATION Installation and Operation Manual is only related to Indoor Units YUTAKI (S / SCOMBI / S80) combined with Outdoor Units RAS-WH(V)NPE.
  • Page 11 Важна забележка: Съгласно названието на модела е необходимо да се провери какъв е видът на вашата затопляща помпа, какво е съкращението й в това Ръководство за употреба. Това Ръководство за инсталиране и експлоатация се КОДИФИКАЦИЯ НА МОДЕЛИТЕ отнася само за вътрешни тела YUTAKI (S / SCOMBI / S80), съчетани с външни тела RAS-WH(V)NPE.
  • Page 12  YUTAKI SERIES OUTDOOR UNIT · UNIDAD EXTERIOR · AUßENEINHEIT · UNITÉ EXTÉRIEURE · UNITÀ ESTERNA · UNIDADE EXTERIOR · UDENDRS AGGREGAT · BUITENTOESTEL · UTOMHUSENHET · ΕΞΩΤΕΡΙΚΗ ΜΟΝΑΔΑ ВЪНШНО ТЯЛО · VENKOVNÍ JEDNOTKA · VÄLISEADE · KÜLTÉRI EGYSÉG · ĀRA IERĪCE · IŠORINIS ELEMENTAS · JEDNOSTKA ZEWNĘTRZNA ·...
  • Page 13 INDEX INDICE 1 GENERAL INFORMATION 1 INFORMAZIONI GENERALI 2 SAFETY 2 SICUREZZA 3 IMPORTANT NOTICE 3 NOTA IMPORTANTE 4 TRANSPORTATION AND HANDLING 4 TRASPORTO E MOVIMENTAZIONE 5 BEFORE OPERATION 5 PRIMA DEL FUNZIONAMENTO 6 NAME OF PARTS 6 NOME DEI COMPONENTI 7 UNITS INSTALLATION 7 INSTALLAZIONE DELLE UNITÀ...
  • Page 14 INNEHALLSFÖRTECKNING INDEKS 1 ALLMÄN INFORMATION 1 ÜLDTEAVE 2 SÄKERHET 2 OHUTUS 3 VIKTIGT MEDDELANDE 3 TÄHTIS TEADE 4 TRANSPORT OCH HANTERING 4 TRANSPORT JA KÄSITSEMINE 5 FÖRE DRIFT 5 ENNE TÖÖLE PANEMIST 6 DELARNAS NAMN 6 OSADE NIMED 7 INSTALLATION AV ENHETER 7 SEADMETE PAIGALDAMINE 8 KYLRÖR OCH PÅFYLLNING AV KYLMEDIUM 8 JAHUTUSTORUSTIK JA JAHUTUSVAHENDIGA TÄITMINE...
  • Page 15 SPIS TREŚCI OBSAH 1 INFORMACJE OGÓLNE 1 VŠEOBECNÉ INFORMÁCIE 2 BEZPIECZEŃSTWO 2 BEZPEČNOSŤ 3 WAŻNE INFORMACJE 3 DÔLEŽITÉ UPOZORNENIE 4 TRANSPORT ZEWNĘTRZNY I WEWNĘTRZNY 4 PREPRAVA A MANIPULÁCIA 5 CZYNNOŚCI POPRZEDZAJĄCE URUCHOMIENIE 5 PRED PREVÁDZKOU 6 CZĘŚCI SKŁADOWE 6 NÁZVY ČASTÍ 7 MONTAŻ...
  • Page 16 1 GENERAL INFORMATION 1.1 GENERAL NOTES © Copyright 2021 Johnson Controls-Hitachi Air Conditioning HITACHI makes every effort to offer correct, up-to-date Spain, S.A.U. – All rights reserved. documentation. Despite this, printing errors cannot be controlled by HITACHI and are not its responsibility.
  • Page 17 In case that the CD-ROM is • Signal words (NOTE, DANGER and CAUTION) are used missing or it is not readable, please contact your HITACHI to identify levels of hazard seriousness. Definitions for dealer or distributor.
  • Page 18 TRANSPORTATION AND HANDLING Start-up and Operation: Check to ensure that all the stop valves are fully opened and no obstacle exists at the inlet/outlet sides before start-up and during the operation. Maintenance: Periodically check the high pressure side pressure. If the pressure is higher than the maximum allowable pressure, stop the system and clean the heat exchanger or remove the cause. Maximum Allowable Pressure and High Pressure Cut-out Value: Refrigerant Maximum Allowable Pressure (MPa) High Pressure Switch Cut-out Value (MPa) R410A 4.15 4.00 ~ 4.10 N O T E The label for the vessel under PED are attached on the high pressure vessel. The pressure vessel capacity and vessel category are indicated on the vessel. Location of High Pressure Switch Structure of High Pressure Switch Contact Point...
  • Page 19 NAME OF PARTS 6 NAME OF PARTS 7T143459 Nº Part Name Nº Part Name Compressor Receiver Heat exchanger Accumulator Propeller fan (2pcs.) Check joint Fan motor (2pcs.) Electrical box Strainer High pressure switch for protection Distributor Sensor for refrigerant pressure Reversing Valve Pressure switch for control Micro-computer control expansion valve...
  • Page 20 UNITS INSTALLATION 7 UNITS INSTALLATION 7.1 OUTDOOR UNITS INSTALLATION C A U T I O N • Transport the products as close to the installation location as practical • Cleaning liquid shall be collected after cleaning. before unpacking. • Pay attention not to clamp cables when attaching the service cover to • Do not put any material on the products. avoid electric shock or fire. • Apply four lifting wires on to the outdoor, when lifting it by crane. • Keep clearance between the units of more than 100mm, and avoid obstacles that may hamper air intake, when installing more than one • Install the outdoor unit with sufficient clearance around it for operation units together. and maintenance as shown in the next figures. Install the outdoor unit where good ventilation is available. • Install the outdoor unit in the shade or not exposed to direct sunshine or direct radiation from high temperature heat source. • Do not install the outdoor unit where is a high level of oil mist, salty air or sulphurous atmosphere.
  • Page 21 UNITS INSTALLATION Blocked in Inlet Side 100 mm or more of the side space is acceptable on the service Allow 100 mm of space between units. Leave open both right and left sides. cover side. Be sure to use the fan direction guide. Allow 100 mm of space between units. Leave open both right and left sides.
  • Page 22 UNITS INSTALLATION 7.1.2 Installation place provision  Concrete Foundation 1 Foundation could be on flat and is recommended be 5 The whole of the base of the outdoor unit should be installed 100-300 mm higher than ground level. on a foundation. When using vibration-proof mat, it should also be positioned the same way.
  • Page 23 REFRIGERANT PIPING & REFRIGERANT CHARGE  Suspended unit C A U T I O N Suspend the unit as the drawing Pay attention to the following for installation: indicates. Installation shall ensure that outdoor unit Wall bracket (*) Ensure that wall can resist the Outdoor will not incline, vibrate, make noise or fall unit weight indicated in specification label down by a blast of wind or in an earthquake.
  • Page 24 REFRIGERANT PIPING & REFRIGERANT CHARGE 8.2 PIPING CONNECTION FOR OUTDOOR UNIT  Gas pipe accessory (only for 8 and 10 HP) a. For the front and side piping For RAS-(8/10)WHNPE, the gas pipe accessory with a flare nut Front piping hole (factory-supplied silencer) shall be brazed to the field supplied Side piping hole gas line, and connected to the gas valve.
  • Page 25 REFRIGERANT PIPING & REFRIGERANT CHARGE 2 Mount the piping cover in order to avoid water entering into the unit. Seal the holes where pipes and wires are inserted, Do not apply by using a insulation (field-supplied). two spanners at this position. If Stop valve 3 If the field-supplied piping is connected with stop valves applied, leakage...
  • Page 26 REFRIGERANT PIPING & REFRIGERANT CHARGE 8.4 REFRIGERANT CHARGE • Insulate the liquid piping completely to avoid a decrease of C A U T I O N performance; if not, it will cause sweating on the surface of the pipe. • Do not charge OXYGEN, ACETYLENE, or other flammable and • Charge refrigerant correctly. Overcharging or insufficient charging poisonous gases into the refrigerant because an explosion can occur.
  • Page 27 DRAIN PIPING 9 DRAIN PIPING 9.1 DRAIN DISCHARGING BOSS When the base of the outdoor unit is temporarily utilized as a Model Applicable Model drain receiver and the drain water in it is discharged, this drain DBS-26 All units boss is utilized to connect the drain piping. ...
  • Page 28 ELECTRIC WIRING 10 ELECTRIC WIRING 10.1 GENERAL CHECK 1 Ensure that the field-supplied electrical components (mains 5 Check to ensure that power supply has an impedance low power switches, circuit breakers, wires, connectors and wire enough to warranty not reduce the starting voltage more terminals) have been properly selected according to the than 85% of the rated voltage.
  • Page 29 ELECTRIC WIRING 10.2.1 Setting of DIP Switches for Outdoor Unit   Quantity and Position of DIP Switches DSW3: Capacity The location is as follows: Factory setting RAS-(4-10)WH(V)NPE RAS-4WHVNPE RAS-5WHVNPE RAS-6WHVNPE 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 RAS-4WHNPE RAS-5WHNPE...
  • Page 30 ELECTRIC WIRING 10.3 COMMON WIRING C A U T I O N C A U T I O N All the field wiring and electrical components must comply with local codes. • Pay attention to the connection of the operating line. Incorrect connection may cause the failure of PCB. 10.3.1 Electrical wiring between indoor unit • Check to ensure that the field supplied electrical components and outdoor unit (mains power switches, circuit breakers, wires, connectors and wire terminals) have been properly selected according to the electrical...
  • Page 31 COMMISSIONING 11 COMMISSIONING • DO NOT PUSH THE BUTTON OF THE MAGNETIC SWITCH(ES), it When installation is completed, perform test run according to the will cause a serious accident. following procedure, and hand over the system to the customer. • Do not touch any electrical components for more than three minutes Confirm that the electrical wiring and the refrigerant piping are after turning OFF the main switch. correctly connected. •...
  • Page 32 Johnson Controls-Hitachi Air Conditioning Spain, S.A.U. Ronda Shimizu, 1 - Políg. Ind. Can Torrella 08233 Vacarisses (Barcelona) Spain © Copyright 2021 Johnson Controls-Hitachi Air Conditioning Spain, S.A.U. – All rights reserved. Printed in Spain...