Proceed as follows to mount the drain:
Place the profile seal in the recess of the drain unit.
Mount the drain unit with profile seal on the drain opening of the
bathtub from below.
Fit the valve top in the drain opening.
Place the fixing screw in the drain unit and tighten using a flat-blade
screwdriver.
After the overflow and the drain have been mounted, you must connect
them both using the overflow pipe. Proceed as follows:
Requirements:
The overflow is mounted in the overflow opening.
n
n
The drain is securely mounted on the base of the bathtub.
NOTICE! Connections where the pipes are not inserted far
enough into each other become leaky. For this reason, maintain
a minimum insertion depth of 15 mm for every connection.