Leuze electronic LSIS 472i Series Operating Instructions Manual page 51

Smart camera for compartment fine positioning
Table of Contents

Advertisement

Table 13.4:
Housing
Connection technology
Degree of protection
Weight
Dimensions
Lens cover
Table 13.5:
Ambient temperature (operation)
Temperature range (storage)
Air humidity
Vibration
Shock
Continuous shock
Electromagnetic compatibility
Device with heating
Table 13.6:
Operating voltage U
Power consumption
Structure of the heating
Warmup time
Minimum conductor cross section
Table 13.7:
Ambient temperature (operation)
Temperature range (storage)
Leuze electronic
Mechanical data
Environmental data
Electrical equipment
B
Ambient temperature
Diecast aluminum
M12 connectors
IP 65, IP 67
Each with screwed-on M12 connector
500 g
(H x W x D) 113 mm x 75 mm x 55 mm
Glass
0 °C ... +45 °C
-20 °C ... +70 °C
Maximum 90 % rel. humidity, non-condensing
IEC 60068-2-6, test Fc
IEC 60068-2-27, test Ea
IEC 60068-2-29, test Eb
EN 61000-6-2, EN 61000-6-4
24 VDC ± 20 %
Devices with heating do not have UL approval
20 W maximum
Housing heating and separate heating of the optics glass
Minimum 30 min at +24 VDC and an ambient temperature
of -35 °C
Conductor cross section of at least 0.75 mm² for the sup-
ply voltage supply line.
Notice:
Wiring through of the voltage supply to multiple heating
devices is not permissible.
Standard, M12 ready-made cable not usable (insufficient
conductor cross section).
-35 °C ... +45 °C
-20 °C ... +70 °C
LSIS 472i
Technical data
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lsis 472i m45-i1Lsis 472i m45-i1-h

Table of Contents