CONFIGURATION > PROGRAMS
Select
Click on the [Configure compartment fine positioning] button.
Configure compartment fine positioning
Figure 9.4:
Enter the type and diameter of the marking.
Enter the distance between rack profile and lens cover of the device.
For a single-depth warehouse, enter the same distance under
Enter the positioning accuracy for the active check program.
The positioning accuracy is determined over a rectangular positioning area depending on the diameter
of the marking. If the device sees the marking within this area, positioning of the high-bay storage device
is concluded (I05 ... IO8 = 1).
Example:
• Diameter of the marking: 15 mm
Positioning accuracy X: 5 mm
Positioning accuracy Y: 5 mm
If the device sees the marking within an area of 25 mm x 25 mm around the center of the marking, all
switching outputs switch to 1.
Enter the offset values for the active check program.
The offset can be used to enter a deviation of the positioning relative to the middle of the marking, e.g.,
to take into account the difference in positioning between loading position and unloading position of the
high-bay storage device.
Confirm all entries with [OK].
9.3.5
Calibrating
During device calibration, the measurement distance is calibrated with the diameter of the marking.
CONFIGURATION > PROGRAMS
Select
Select the active check program (
CONFIGURATION > PROGRAM > Tools > Calibration
Select
Tool configuration – Calibration
The
Leuze electronic
Extended configuration – Leuze electronic webConfig tool
.
dialog
.
Rack Near
Rack Far
or
).
dialog is displayed.
LSIS 472i
Rack Near
Rack Far
and
.
.
33