Tool configuration – Calibration
Figure 9.5:
NOTICE
Recalibration required if the measurement distance changes!
 If the distance for the check program (
tion must be adjusted.
 Calibrate via the point detectors if necessary.
 Enter the diameter of the marking (hole or reflector) in the selection list [Calibration block length].
 Click on the [Accept values] button.
Setting the offset
For the current check program, you can set additional distances (offsets) for the positioning. By means of
the offset value, it is possible to detect, e.g., the position difference between loading position and unloading
position of the high-bay storage device.
• If the offset values are 0, the smart camera positions the high-bay storage device exactly on the
marking.
• If offset values are set, the control signals a corresponding position deviation.
Example: with offset Y = 20 mm, the high-bay storage device is positioned 20 mm below the mark-
ing.
The offset is not visualized in the image.
CONFIGURATION > PROGRAMS
 Select
 Select the active check program (
CONFIGURATION > PROGRAM > Tools > Calibration > Offset
 Select
Tool configuration – Offset
The
Leuze electronic
Extended configuration – Leuze electronic webConfig tool
dialog
Rack Near
or
.
Rack Near
Rack Far
or
dialog is displayed.
LSIS 472i
Rack Far
) changes in the application, the calibra-
).
.
34