Electrical connection

7.1

Overview

The electrical connection of the device is performed using M12 connectors.
1
2
3
Figure 7.1:
Position and designation of the M12 connections
For all connections (connection cable, interconnection cable, etc.), use only the cables listed in
the accessories (see chapter 14.2 "Cables-Accessories").
CAUTION
Safety Notices!
 Before connecting the device please ensure that the supply voltage matches the value printed on the
nameplate.
 Only allow competent persons to perform the electrical connection.
 The shielding connection is done via the M12 connector housing.
 Ensure that the functional earth (FE) is connected correctly.
Fault-free operation is only guaranteed if the functional earth is connected properly.
All electrical disturbances (EMC couplings) are discharged via the functional earth connection.
 If faults cannot be rectified, take the device out of operation. Protect the device from accidentally being
started.
NOTICE
UL applications
 For UL applications, use is only permitted in class 2 circuits in accordance with the NEC (National Elec-
tric Code).
Leuze electronic
1
3
SERVICE: host and service interface (Ethernet); M12-socket (D-coded)
PWR: supply voltage (18 V ... 30 VDC), IO1 ... IO4; M12 plug (A-coded)
BUS OUT: RS 232 interface, IO5 ... IO8; M12 socket (A-coded)
2
LSIS 472i
Electrical connection
21