7.4

SERVICE

4-pin M12 socket (D-coded)
1
Figure 7.4:
Pin assignment of the SERVICE connection
Table 7.3:
Pin
1
2
3
(Thread for M12
connector plug)
Connection cables: see table 14.2
Ethernet cable assignment
1
Figure 7.5:
Cable assignments - SERVICE on RJ-45
Designed as shielded cable, max. length 100 m.
Pin (M12)
1
2
3
4
NOTICE
Self-configured cables for Ethernet connection!
 The depicted core colors apply only for interconnection cables from Leuze electronic.
The depicted core colors are not compliant with EIA/TIA 568A and EIA/TIA 568B.
 Ensure adequate shielding.
 The entire interconnection cable must be shielded and earthed.
 The RD+/RD- and TD+/TD- wires must be stranded in pairs.
 Use CAT 5 cable for the connection.
Leuze electronic
4
3
2
SERVICE pin assignment
Designation
TD+
RD+
TD-
FE
2
3
4
Designation
TD+
RD+
TD-
RD-
Assignment
Transmit Data +
Receive Data +
Transmit Data -
Connection cable shield
The shield of the connection cable is on the thread of
the M12 connector plug.
The thread of the M12 connector plug is part of the
metallic housing. The housing is at the same poten-
tial as functional earth.
Pin/core color (RJ-45)
1/yellow
3/white
2/orange
6/blue
LSIS 472i