Inverting Output Values For Pan/Tilt - EuroLite DMX Scan Control 192 MK2 User Manual

Table of Contents

Advertisement

Available languages

Available languages

Inverting Output Values for Pan/Tilt

4. Select the desired scanner.
5. Press TAP/DISPLAY to switch between 8-channel and 16-channel mode.
The display shows either 'ASSXX XX | X/Y 08CH' or 'ASSXX XX | X/Y
16CH'.
8-channel mode: You can assign the PAN/TILT movement for 24 scanners.
In 8-channel mode, you can save PAN/TILT for page A and page B.
16-channel mode: You can assign the PAN/TILT movement for 12
scanners. In 16-channel mode, you can save PAN/TILT only for page A or
page B.
6. If necessary, you can use PAGE SELECT to switch between levels Page A
and Page B.
7. While you keep MODE pressed, press the SCENES button. All LEDs should
flash briefly and thus indicating that the DMX channel has been assigned.
The button SCENES 1 stands for DMX channel 1, SCENES 2 for DMX
channel 2 and so on.
8. Repeat steps 3 – 7 to assign the pan/tilt channels of further scanners.
1. Enable programming mode.
2. Simultaneously press FINE and MODE. The LED REVERSE lights up and
thus indicates that the device is in reverse mode.
3. With BANK UP/DOWN you can switch between Pan and Tilt. The
corresponding LED indicates your selection.
4. Select the desired scanner.
36/56
00116794, Version 1.0

Hide quick links: