TABLE 2-1.
RA6790/GM
OPTIONAL BANDPASS FILTER LIST
*Mechanical Filters. All Others are Crystal Filters.
Shape Factor Differential
Racal
Bandwidth
Description
3 dB: 60 dB
Delay
ILS
Number
*0.3 kHz
Symmetrical BPF
1 :6.7
-
07883-1
* 1.0 kHz
Symmetrical BPF
1 :4.5
-
07883-2
* 3.2 kHz
Symmetrical BPF
1 :2.7
-
07883-3
*4.0 kHz
Symmetrical BPF
1 :2.5
.
-
3600001
* 5.0 kHz
Symmetrical BPF
1:2.5 .
-
3600002
* 6.0 kHz
Symmetrical BPF
1 :2.3
-
078834
* 450
Hz to
3000 Hz
ISB/USB BPF
1: 1.92
-
07883 .. 5
*-
450 Hz to 3000' Hz
ISB/LSB BPF
.1: 1.92
-
07883-6
* 350 Hz to 2700 Hz
USB BPF
1: 1.66
-
08669
* 300 Hz to 2200 Hz
USB BPF
I: 1.97
-
08771
1.0 kHz
Symmetrical BPF
1:6
25
3600003
3.0 kHz
Symmetrical BPF
1 :6
13
3600004
6.0. kHz
Symmetrical BPF
1 :6
10
3600005
1.0 kHz
Symmetrical BPF
1:2.5
1080
3600006
3.0 kHz
Symmetrical BPF
1 :2.5
360
3600007
6.0 kHz
Symmetrical BPF
1 :2.5
180
3600008
0.125 kHz
Symmetrical BPF
1 :5.33
-
08699
0.4 kHz
Symmetrical BPF
1:6.2
-
08406
1.2
kHz
Symmetrical BPF
1 :6
-
08407
6.8 kHz
Symmetrical BPF
1:3.3
-
08408
-
350 Hz to 3050 Hz
ISB/LSB BPF
I: 1.6
800
08409
350 Hz to 3050 Hz
ISB/USB BPF
1: 1.6
800
08410
.-0.4 kHz
Symmetrical BPF
1 :2.5
2000
08411..-
-1.1
kHz
Symmetrical BPF . 1 :2
1000
08412 ......
f-'3.24 kHz
Symmetrical BPF
1: 1.33
1000
08413-
'-6,8 kHz
Symmetrical BPF
1· .,
.-
1000
08414.-'
16.0 kHz
Symmetrical BPF
1 :2
40
08415
0.5 kHz
Symmetrical BPF
1 :6
80
08416
1.0 kHz
Symmetrical BPF
1 :6
40
08417
2.0 kHz
Symmetrical BPF
1 :6
20
08418
3.0 kHz
Symmetrical BPF
1:6
20
08419
6.0 kHz·
Symmetrical BPF
1:6
20
08420
0.075 kHz
Symmetrical BPF
.1 :6:67
-
08589
.,
Carefully push down on the fIlter to insert the pins into the sockets. Relatively light
pressure is required to insert the pins into the sockets. If the fIlter does not easily
slide into place, recheck the pin/socket alignments.
3. Insert the appropriate fIlters into fIlter positions FL2 through FL 7 (as required), uslng
the procedures described in steps 1 and 2.
4. After all filters have been inserted, visually inspect the fllters to insure that they are
properly seated. The bottom of the fIlters should be flat against the surface of the
A4 board.
5. Replace the RF shield over the fIlters and secure the shield in place by tightening the
three screws.
NOTE
If the Receiver is to be equipped for operation from a remote control device
or in the ISB mode, continue with the procedures described in Paragraphs
2-8

Advertisement

loading