TM-2
.'
..
Table B-1.
Command and Monitor Data and Format (Cont.)
G.
Attenuation (A30)
The attenuation number defines the amount of attenuation placed in the
signal path during the manual attenuation AGe mode, or the minimum attenuation
during the variable threshold modes.
The "attenuation varies from zero (no
attenuation) to 150 (maximum attenuation) with no change between
numb~rs
greater'"" "
. than 3 ·'dB.
H.
Status (85)
The status command when sent to the receiver controls its operating status.
In the monitor mode the status provides summary error indication.
1)
Command Status
Command status may only be sent to one receiver, since commands 5 and 6
create monitor data streams.
The status commands are:
1
Set the receiver to local control.
2 - Set the receiver to remote control.
3 - Execute the BITE self test routine.
4
Terminate the BITE self test routine.
S - Report currently installed bandwidths.
6 - Report BITE results.
7 - Force bandwidth setup.
S
Enable remote AGC dump.
9 - Inhibit remote AGC dump.
Command 1 _ Sets the receiver to local control mode.
This command is invalid in
override mode.
Command 2 - Sets the receiver to the remote control.
Command 3 - Starts receiver Bite (Built in Test) routine.
This command, when excepted causes the receiver to output a colon
(:) until bite is finished it will output a colon response to any
talk command.