ABS 2.0 Service Manual
A
I
DJUSTMENT
CE
The conveyor assembly must be installed before beginning this procedure.
Place the measuring cup under the ice
dispenser.Select the "Ice Dispense
1.
Calibration" Icon from the Unit setup
menu as shown in Figure 73.
From the Ice Dispense Calibration
Menu Select the Cup Size, Amount of
2.
Ice and Press "DISPENSE" button as
shown in Figure 74. and measure the
weight of the Ice.
If weight is not correct adjust the Ice
dispense time by pressing the up/down
3.
arrow as shown in Figure 75. if correct
weight is obtained. Save the setting by
pressing the save button.
4.
Repeat the process for all remaining cup sizes with different amount of Ice and save the setting.
S
S
-
AVING THE
ET
Select preferences in respective set up and press "SAVE" icon shown in Figure 76. to save the setting of the menu
Publication Number: 621058590SER
UP
Table 22
Figure 73.
Figure 74.
Figure 75.
Figure 76.