Unstable measurement condi‐
tion
79
Auto filtering
87
The sensor is stabilizing
10.4
Transmitter diagnostic events
Transmitter diagnostic events
ID/
Diagnostic
Icons
96
Mass flow
97
Mass flow
98
Mass flow
99
Mass flow
FC310 (From firmware 4.0)
Operating Instructions, 06/2018, A5E44036384-AA
Action
Check if air is present in the liquid and that the
flowmeter is operated within its specifications.
Check that the flowmeter is operated within its
specifications. Check other alarms to rule out
HW malfunction.
Check sensor cable connection. Wait 20 sec‐
onds. If the status remains 'Coming' then turn
off the power, wait 5 seconds and turn on the
power again. If the failure continues then con‐
tact your local Siemens representative
Action
Value above alarm limit. Check process condi‐
tions or align limit to normal operation. Adjust
parameter 'Upper alarm limit'.
Value above warning limit. Check process con‐
ditions or align limit to normal operation. Adjust
parameter 'Upper warning limit'
Value below warning limit. Check process con‐
ditions or align limit to normal operation. Adjust
parameter 'Lower warning limit'
Value below alarm limit. Check process condi‐
tions or align limit to normal operation. Adjust
parameter 'Lower alarm limit'
Diagnostics and troubleshooting
10.4 Transmitter diagnostic events
Comments