Siemens SITRANS F Series Operating Instructions Manual page 160

Coriolis flowmeters
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

Technical data
11.8 Pressure - temperature ratings
Table 11-19 ASME B16.5 [bar]
Class /
Group
150 / 2.2
300 / 2.2
600 / 2.2
900 / 2.2
1500 / 2.2
Table 11-20 JIS [bar]
PN (bar)
10K
20K
Table 11-21 DIN 11851 [bar]
PN (bar) / DN
25 / 50-100
40 / 10-40
Table 11-22 DIN 32676 & ISO 2852 [bar]
PN (bar) / DN
10 / 85-219.1
16 / 48.3-76.2
25 / 6.35-42.4
Note
Test pressure
Maximum allowable test pressure (MATP) for the flowmeter and process connection is 1.5
times the nominal pressure up to 150 bar (2176 psi).
160
-50
0
19
19
49.6
49.6
99.3
99.3
110
110
-50
0
14
14
34
34
-50
0
25
25
40
40
-50
0
10
10
16
16
25
25
Temperature TS (°C)
50
100
18.4
16.2
48.1
42.2
96.2
84.4
110
110
Temperature TS (°C)
50
120
14
14
34
34
Temperature TS (°C)
50
100
25
25
40
40
Temperature TS (°C)
50
100
10
10
16
16
25
25
Operating Instructions, 06/2018, A5E44036384-AA
150
200
14.8
13.7
38.5
35.7
77.0
71.3
110
107
150
200
13.4
12.4
33.1
31.6
140
25
40
140
10
16
25
FC310 (From firmware 4.0)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fc310

Table of Contents