WAGNER Zip 52 Finishing Operating Manual page 27

Pneumatic double diaphragm pump spraypack
Hide thumbs Also See for Zip 52 Finishing:
Table of Contents

Advertisement

VERSION 11/2018
Grounding scheme (example)
EX zone
Pump
Floor, static dissipative
B_06945
Part / workstation
Pump
Paint tank
Conveyor
Booth
Spraying stand
Safe operation of the pump is only guaranteed with a grounding
connection.
Connect all grounding cables using a short and direct route.
Procedure
1. Remove the crimp connection delivered with the pump.
2. Attach crimp connection to the grounding cable and re-attach it
to the pump.
3. Ground the product tank to an on-site grounding connection.
4. Ground the other parts of the system to an on-site grounding
connection.
Ex zone
All devices and equipment must be suitable for use in potentially explosive areas.
All paints, flushing agents and waste tanks have to be electrically conductive.
All tanks must be grounded.
ORDER NUMBER DOC 2332848
Product
tank
Cable cross section
4 mm2; AWG 12
6 mm2; AWG 10
16 mm2; AWG 6
16 mm2; AWG 6
16 mm2; AWG 6
Conveyor
Work piece
R max < 1 MΩ
Spraying stand
Zip 52 Finishing
B_04049
27