4.2.7 MAINTENANCE AND REPAIR

Hazard due to improper maintenance and repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
Use only WAGNER original spare parts and accessories.
Do not change or modify the device; if change is necessary, contact WAGNER.
Only repair and replace parts that are listed in Chapter
assigned to the unit.
Do not use any defective components.
Before all work on the device and in the event of work interruptions:
- Relieve the pressure from the spray gun, hoses and all devices.
- Secure the spray gun against actuation.
- Switch off the energy and compressed air supply.
- Disconnect the control unit from the mains. Secure the spray gun against
actuation.
Observe the operating and service manual for all work.

4.2.8 PROTECTIVE AND MONITORING EQUIPMENT

Hazard due to removal of protective and monitoring equipment!
Danger to life and equipment damage.
Protective and monitoring equipment must not be removed, modified or rendered
unusable.
Regularly check for perfect functioning.
If defects are detected on protective and monitoring equipment, the system must
not be operated until these defects are remedied.