4.1.2

Set-up mode

4.1.2.1 Pressure plate forward-backward / door lock open-close

Press the +/– keys simultaneously for about 3 seconds
Indicator: Service menu – Set-up mode
Simultaneously press the +/– keys again for about 3 seconds
Indicator: Caution! – Set-up mode (fl ashes)
Two hand control: Open the hydraulic door lock (5 + 12)
If you simultaneously press the two keys (within 0.6 seconds), the door lock is opened.
If you let go of one of these keys, the action stops
Two hand control: Close the hydraulic door lock (5 + 12)
If you simultaneously press the two keys (within 0.6 seconds), the door lock is closed.
If you let go of one of these keys, the action stops
Two hand control: Press ram forward (5 + 12)
If you simultaneously press the two keys (within 0.6 seconds), you can run the press
ram forwards whilst the counter plate is open. If you let go of one of these keys, the
press ram stops.
Two hand control: Press ram backward (7 + 12)
If you simultaneously press the two keys (within 0.6 seconds), you can run the press ram
backwards whilst the counter plate is open. If you let go of one of these keys, the press
ram stops.

4.1.2.2 To exit set-up mode

Simultaneously press the keys "Close the hydraulic door lock" for about 5 seconds