Transport And Storage; Installation; Installation Location - Bosch Compress 3000 DW FI Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

10 | Transport and storage

Sound pressure level with pipework (at a distance of 2 m)
Dimensions, W x H x D
Net weight (without packaging)
Table 3
4
Transport and storage
WARNING: Transport damage!
▶ Take care when handling the appliance.
▶ To avoid dropping and damaging the
appliance, do not pivot it.
NOTICE: Transport damage!
▶ To avoid transport damage, do not
remove the protective packaging. Wait
until the appliance is at the installation
location to remove the protective
packaging.
▶ Transport and set down the appliance
carefully. Jerky movements can damage
the internal glass-lined coating, the
components and their connections or the
external casing.
▶ Use suitable means of transport to bring
the appliance to the installation location
(special car, pallet truck, etc).
General information
The appliance is delivered on a single pallet and is protected
against transport damage by special packaging.
The appliance must be stored and transported vertically in its
1)
original packaging
and the cylinder must be empty. Ambient
temperatures of -20 °C to +60 °C are permissible for storage
and transport.
1) Horizontal transportation is permitted over short distances,
provided that the conditions described above are fulfilled.
6 720 809 134 (2013/09)
Unit
dB(A)
mm
kg
Manual transport
NOTICE: Damage caused by straps!
▶ Remove the front protective covering
( Fig. 3, [23]).
▶ Make sure that the straps do not scratch
or make indentations on the surface of the
appliance.
▶ Do not attach straps to the appliance
connections.
Straps can be placed around the cylinder in order to position
the appliance in its final location.
5

Installation

▶ The appliance may only be installed by an authorised
contractor.
▶ The heat pump installation must follow the applicable
regulations.
▶ Check that all pipe connections are intact and have not
shaken loose during transportation.
NOTICE: Refrigerant leak!
▶ Only authorised contractors are
permitted to maintain and repair the
refrigerant circuit.

5.1 Installation location

Please note the following when choosing the installation
location:
• The appliance must be installed in a dry, frost-free room.
The supply air temperature must be between -10 °C and
35 °C in order to optimise the appliance performance.
• The appliance must be installed on a sufficiently strong and
level surface.
• The air outlet and air inlet must not be in locations where
there is a risk of explosion cause by gas, steam or dust.
• Ensure that condensate drains correctly.
• The surface below the appliance must be strong enough (the
appliance weighs about 400 kg when the cylinder is filled,
HP270-2E0... HP270-2E1...
40
700 × 1835 × 735
108
125
Compress 3000 DW FII

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents