If in doubt, ask your installer. and knowledge, if they are supervised and have been given instruction in the safe use of the appliance and understand the resulting dangers. Children shall not Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
The duration of the defrost cycle depends on the actual outdoor temperature and the amount of frost on the evaporator. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
Close the • Do not set a too low temperature for cooling. Cooling will also thermostatic valve in a specific room, only if that room is warmer then consume energy. the others. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
• If 2 or more heating circuits are installed, settings for different Changing the required room temperature in the standard display only heating circuits are available and are necessary. affects the heating circuit displayed. 1) This setting is not available in Finlandor Sweden Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
6 720 812 775-02.2O Infographic: Power guard active ▶ Wait a few seconds or press the selector to confirm. Infographic: Additional heat source active Infographic: Defrost function active Infographic: Compressor (Heat pump) active Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
The change applies until the next switching time in the active time program is reached. Cancelling the temperature change: ▶ Turn and press the selector to set the value stored in the time program. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
The user interface operates in automatic mode with the selected time program. If 2 or more heating circuits are installed, this setting only 0010010093-001 applies for the selected heating circuit. The symbol is associated with the switching time on the same line. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
▶ The water heating becomes active immediately. Once the set duration time has expired, the extra DHW cylinder charging switches off again automatically. 0010008200-001 The character to the left of the input field is deleted. 1) Not available for fresh water station. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
Setting the heating and DHW for the holiday program ▶ Open the menu for the holiday program. ▶ Open the Selection of htg circ./DHW menu. 0010008212-001 The holiday program is deleted. 6 720 811 136-34.1O Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
6 720 811 136-15.1O This helps to select the correct time program, e.g. “family” or “night shift”. Table 5 Time program settings for heating Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
Table 9 Time program settings for DHW [Prioritise DHW for] and [Heating priority for]. Prioritise DHW Duration of DHW heating. Heating priority Duration of heating mode. Table 7 Settings for the DHW alternating operation Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
Page 14
▶ Only carry out thermal disinfection/daily heat-up outside normal Table 13 Settings for the circulation hours of use. ▶ Make sure that a thermal mixer is installed. If in doubt, ask your installer. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
▶ After a long absence, check the operating pressure of the heating system and check the pressure gauge of the solar system if applicable. ▶ Do not switch off the solar system during long absences. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
If enabled the room temperature is decreased to the temperature set for cooling operating mode. No cooling is done if the holiday program is active. Table 19 Settings in the EM system data menu Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
Cumulated energy consumed by the heat pump in temperature cooling mode. Table 24 Information about pool Pool Cumulated energy consumed by the heat pump in pool heating mode. Table 28 Energy consumption data for heat pump Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
Table 32 Your contractor must enter the ID no. here. Faults on additional heat source: ▶ Check the display of the additional heat source for information. ▶ Reset the additional heat source. ▶ If the fault persists; contact your contractor. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
▶ Take out the strainer and clean it by running water over it or by pressure cleaning. ▶ Reinstall the strainer. For proper assembly, make sure that the guide bumps fit into the recesses in the valve. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
Water is expelled from the safety valve during heat-up. Never close the If the heat pump has sound insulation, ice can form. In this case there is safety valve. risk of falling. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
The fins have sharp edges. Risk of cuts in the event of careless handling. ▶ Wear protective gloves on your hands to protect against cuts. ▶ Proceed with caution in order not to damage the fins. Fig. 8 The heat pump condensation catch pan Drain pan Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
For details of the SmartGrid, refer to the product website. with a free RJ45 output are necessary. This can lead to additional costs. The Bosch HomeCom Easy app is required to control the system using a mobile phone. Functionality is not available in all national markets. For The login data are lost when the IP module is exchanged.
Data Protection Officer, Information Security and Privacy (C/ISP), The 3-way valve distributes thermal energy to the heating circuits or the Robert Bosch GmbH, Postfach 30 02 20, 70442 Stuttgart, GERMANY. DHW cylinder. It has two defined settings so that heating and DHW...
Page 24
Depending on the type of frost protection selected, the outdoor unit is switched on if the outside temperature or room temperature falls below a certain critical threshold. Frost protection prevents the heating system from freezing up. Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
Need help?
Do you have a question about the Compress 7000 AWM/AWMS 5-17 and is the answer not in the manual?
Questions and answers