8.4 "Prog" submenu - Operating modes

You can set 7 different operating times in the "Prog" submenu.
• Manual
• P1
• P2
• P3
• Full
• Off

8.4.1 "Manual" operating mode

Selecting this operating mode puts the appliance into
continuous operation in order to keep the temperature at the
set value for a longer period of time. The heat appliance can be
set in the main menu using the "Mode" function
( chapter 8.5).
Fig. 17 "Manual" operating mode

8.4.2 "P1", "P2" and "P3" operating modes

"P1" operating mode
Selecting this menu causes the appliance to run according to
the factory-set operating times ( "P1" operating time,
page 22).
Compress 3000 DW FII
"P2" and "P3" operating modes
Selecting this menu causes the appliance to run according to
the user-set operating times ( "P2" and "P3" operating times,
page 22).

8.4.3 "Full" operating mode

In this operating mode, two heat appliances are used at the
same time: the heat pump and the electric booster heater.
Fig. 18 "Full" operating mode
The water temperature can be set to between 30 °C and 70 °C.
As soon as the set DHW temperature is reached, the appliance
switches from the "Full" operating mode back to the previously
set operating mode.
"Quick" activation of the "Full" operating mode
▶ Press and hold the "+" and "-" buttons for more than
3 seconds.
6720646160-37.1V

8.4.4 "OFF" operating mode

In this operating mode, the appliance is switched off. If
necessary, the electric booster heater is switched on by itself
for the frost protection function.
The appliance performance decreases in
"Full" operating mode. For this reason, it
must only be used when the water
temperature needs to be increased rapidly.
Both heat appliances are used at the same
time until the desired temperature is
reached.
Only the electric booster heater is used at
temperatures above 60 °C.
The display shows "Full" until the desired
temperature is reached.