SM Split CS Series Heat Pump Compressor Ohms .............31 Document Conventions ............3 Key to Symbols............3 Operating Temperatures and Pressures......32 Safety Warnings..............3 Maintenance ..............36 Water Side Pressure Drop in PSIG ........36 Model Nomenclature ............4 Decommissioning Information ........... 37 CS/Air Handler Pairing ............5...
SM Split CS Series Heat Pump Document Conventions | 3 DOCUMENT CONVENTIONS Key to Symbols WARNING: When working on equipment, always observe precautions described in Warnings the literature, tags, and labels attached to Warnings in this document are identified by the unit.
4 | Model Nomenclature SM Split CS Series Heat Pump MODEL NOMENCLATURE Fig. 1 Model Nomenclature Subject to change without prior notice 8733825873 (2020/05) SM Split CS Series Heat Pump...
6 | SM Split CS Standard Package SM Split CS Series Heat Pump SM SPLIT CS STANDARD PACKAGE A heat pump operating under extreme conditions will have limitations on air/fluid flow rates and/or temperatures. NOTICE: 50° F Minimum Entering Water...
SM Split CS Series Heat Pump Unit Installation | 7 UNIT INSTALLATION Air Handler Location This section contains information on the following: Locate the air handler unit in an indoor area that allows easy removal of the filter and access panels,...
Supply and return piping must be as large as the Refer to the Bosch SM Split CS ESS unit connections on the heat pump (See Table #2 (Engineer Submittal Sheet) for water-flow for any line size with an installation 25 feet and rates.
SM Split CS Series Heat Pump Refrigerant Lines | 9 Always check carefully for water leaks and repair refrigerant metering device, and that the liquid appropriately. Units are equipped with female pipe pressure at the refrigerant metering device is thread fittings. Consult Unit Dimensional Drawings sufficient to produce the required refrigerant on page #39.
Page 10
10 | Refrigerant Lines SM Split CS Series Heat Pump Pressurize the refrigerant line set and air handler to 150lbs with dry nitrogen through the ports The air handler is factory supplied with a provided on the self service valves. Check line set holding charge of dry nitrogen.
BVA-48WN1-M20 BVA-60WN1-M20 CS MODEL SM024-1CSC SM024-1CSN SM036-1CSC SM036-1CSN SM048-1CSC SM048-1CSN SM060-1CSC SM060-1CSN Table 4 Charge Adjustments (oz) for SM Split CS when Paired with BOSCH BVA2.0 Subject to change without prior notice SM Split CS Series Heat Pump 8733825873 (2020/05)
Page 12
SM024-1CSN SM036-1CSC SM036-1CSN SM048-1CSC SM048-1CSN SM060-1CSC SM060-1CSN Table 5 Charge Adjustments (oz) for SM Split CS when Paired with BOSCH BMAC TXV Adjustments for SM Split CS when Paired with BOSCH BVA2.0 Air Handler Model BVA-24WN1-M20 BVA-36WN1-M20 BVA-48WN1-M20 BVA-60WN1-M20 CS MODEL...
Page 13
BMAC: 1 Turn Closed SM: None SM060-1CSN BMAC: 1 Turn Closed Table 7 TXV Adjustments for SM Split CS when Paired with BOSCH BMAC BVA2.0 Rated Airflow Adjustment when Paired with SM Split CS Models CS Model Air Handler Full-Load-Rated...
14 | Water Quality Table SM Split CS Series Heat Pump WATER QUALITY TABLE Water Quality Water Characteristic Acceptable Value POTENTIAL PROBLEM Copper Cupro-Nickel pH (Acidity/Alkalinity) 7–9 7–9 SCALING Hardness (CaCO , MgCO < 350 ppm < 350 ppm Ryznar Stability Index 6.0–7.5...
SM Split CS Series Heat Pump Water Quality Table | 15 Electrical Refer to electrical component box layout. (See Fig. 5) WARNING: UNIT OPERATION AND SAFETY HAZARD Field wiring must comply with local and national electric codes. WARNING: UNIT OPERATION AND SAFETY...
16 | Safety Devices and the UPM Controller SM Split CS Series Heat Pump Safety Devices and the UPM Controller If the thermostat is provided with a malfunction light powered off of the common (C) side of the transformer, a jumper between “R”...
Page 17
SM Split CS Series Heat Pump Safety Devices and the UPM Controller | 17 For Reference UPM Board Factory Default Settings Only TEMP 26°F LOCKOUT RESET ALARM PULSE TEST Table 10 UPM Board Factory Default Settings Fig. 7 Sensor location...
Page 18
18 | Safety Devices and the UPM Controller SM Split CS Series Heat Pump to R, the board must be manually powered off drops below or remains at the freeze-limit trip and powered back on to exit the hard lock out.
SM Split CS Series Heat Pump Typical System Setup | 19 TYPICAL SYSTEM SETUP For Reference Only. A typical setup is shown for illustration purposes only. Fig. 9 Typical system setup [1] Flex Duct Connection [2] Low Voltage Control Connection...
20 | Typical System Setup SM Split CS Series Heat Pump Cooling Tower/Boiler Systems Piping SPECIFIC APPLICATION CONSIDERATIONS NOTICE: Water piping exposed to extreme Well Water Systems low ambient temperatures is subject to freezing. Copper is adequate for ground water that is not high in mineral content.
SM Split CS Series Heat Pump Post-Installation System Checkout | 21 POST-INSTALLATION SYSTEM SYSTEM OPERATION CHECKOUT UNIT START-UP After completing the installation and before 1. Place the UPM board in “Test” mode. energizing the unit, the following system checks 2. Set the thermostat to the highest setting.
Page 22
22 | Sequence of Operation SM Split CS Series Heat Pump Some accessories have a built-in delay, and hence, compressor operation is not immediate. See “Field-Installed Accessories” section on page #23 for more detail. When the thermostat calls for second-stage cooling (Y2) the second stage (or full-compressor capacity) is initiated.
SM Split CS Series Heat Pump Standard Factory-Installed Components | 23 STANDARD FACTORY-INSTALLED SmartStart Assist COMPONENTS The SM series is available with the SmartStart Assist device as a field-installed accessory. This Pump/Valve Relay device reduces starting (in-rush) current for The factory-installed pump/valve relay can be used compressors by 45% to 65%.
24 | Field-Installed Accessories SM Split CS Series Heat Pump SmartStart Assist Specifications SmartStart Assist Specifications Rated Operational Voltage: 208/230VACrms +/- 15% 50-60 Hz Environmental Operating Range: -4° to 149°F (-20° to 65°C); < 95% @ 40 C relative humidity,...
Page 25
SM Split CS Series Heat Pump Field-Installed Accessories | 25 Fig. 13 SmartStart Assist Modes of Operations (Overcurrent Condition and Incomplete Ramp Alarm) SmartStart Assist Modes of Operation Notes 4. In the case of an under voltage, the SmartStart Assist will shut down and the red LED flashes 1.
Page 26
26 | Field-Installed Accessories SM Split CS Series Heat Pump 6. A detection circuitry provides protection in case of a faulty starting capacitor EMR. In such situations, the red LED will flash four times for five minutes. SmartStart Assist will check the...
SM Split CS Series Heat Pump Check-Out Sheet | 27 CHECK-OUT SHEET Customer Data Customer Name Date Address Phone Unit Number Unit Nameplate Data Unit Make Model Number Serial Number Refrigerant Charge (oz) Compressor: RLA Blower Motor: FLA (or NPA)
28 | Troubleshooting SM Split CS Series Heat Pump TROUBLESHOOTING A possible fault may be one or a combination of causes and solutions. Check each cause and adopt “process of elimination” and or verification of each before making any conclusion.
Page 29
SM Split CS Series Heat Pump Troubleshooting | 29 Unit Troubleshooting Problem Possible Cause Checks and Corrections Unit Oversized Recalculate heating and or cooling loads. If the thermostat is installed near a supply air grill, UNIT SHORT Thermostat relocate thermostat. Adjust the heat anticipator.
30 | Troubleshooting SM Split CS Series Heat Pump SmartStart Assist Troubleshooting Red Led Relay Condition Action Contact* FULLY ON + 11/12 Min. recovery time between starts Auto reset when minimum recovery and/or recovery time between stop to time elapses...
SM Split CS Series Heat Pump Troubleshooting | 31 UPM LED Status Indicator (Blink Code) Information The LED status indicator is found on the UPM board. See Fig. 6 on page #16. Indication Color Blinks Description GREEN Solid 18–30 VAC power is present...
32 | Operating Temperatures and Pressures SM Split CS Series Heat Pump OPERATING TEMPERATURES AND PRESSURES Operating Temperatures and Pressures Cooling Heating Water Entering Suction Discharge Water Suction Discharge Temp. Water Water Pressure Pressure Temp. Temp. Pressure Pressure Drop Temp.
Page 33
SM Split CS Series Heat Pump Operating Temperatures and Pressures | 33 Operating Temperatures and Pressures Cooling Heating Water Entering Suction Discharge Water Suction Discharge Temp. Water Water Pressure Pressure Temp. Temp. Pressure Pressure Drop Temp. Model Temp. F Flow...
Page 34
34 | Operating Temperatures and Pressures SM Split CS Series Heat Pump Operating Temperatures and Pressures Cooling Heating Water Entering Suction Discharge Water Suction Discharge Temp. Water Water Pressure Pressure Temp. Temp. Pressure Pressure Drop Temp. Model Temp. F Flow...
Page 35
SM Split CS Series Heat Pump Operating Temperatures and Pressures | 35 Operating Temperatures and Pressures Cooling Heating Water Entering Suction Discharge Water Suction Discharge Temp. Water Water Pressure Pressure Temp. Temp. Pressure Pressure Drop Temp. Model Temp. F Flow...
36 | Maintenance SM Split CS Series Heat Pump MAINTENANCE properly determine the cause. Water Side Pressure Drop in PSIG WARNING: ELECTRICAL HAZARD Series Water PD @ Before performing service or maintenance 77°EWT operations on the system, turn off the main with Water power to the unit.
SM Split CS Series Heat Pump Decommissioning Information | 37 Components DECOMMISSIONING INFORMATION Only trained and qualified technicians are allowed Many parts in the Heat Pump can be fully to decommission and dispose of equipment recycled at the end of the product life.
38 | Wiring Diagrams SM Split CS Series Heat Pump WIRING DIAGRAMS Fig. 15 Wiring Diagrams FOR REFERENCE ONLY Actual unit wiring may vary from this example. Always refer to the wiring diagram attached to the unit. Subject to change without prior notice...
SM Split CS Series Heat Pump Dimensional Drawings | 39 DIMENSIONAL DRAWINGS Fig. 16 Dimensional Drawings FOR REFERENCE ONLY Actual unit wiring may vary from this example. Always refer to the wiring diagram attached to the unit. Subject to change without prior notice...
40 | Terminology SM Split CS Series Heat Pump TERMINOLOGY servicing or prior to the disposal of the products or equipment. Acronyms AHJ — Authority Having Jurisdiction Recycling — Referring to the reuse of a recovered fluorinated-greenhouse gas following a basic cleaning ECM —...