Deprag AST40-1 Operating Instruction Booklet page 20

Sequence controller
Table of Contents

Advertisement

ATTENTION
Damage to the device due to overheating!
Make sure that there is sufficient ventilation for the device.
Do not operate the sequence controller in lying position and make sure,
that there is free space at the ventilation slots on the back side of the
device.
More details on the interfaces can be found in Section
6.2 Interface
description.
CAUTION
Observe the minimum bending radii for motor cable.
Non-observance can lead to damages!
During constant movement:
 Minimum bending radius: 110 mm
For one-time bending:
 Minimum bending radius: 55 mm
It is necessary to ensure that there is no mechanical stress on the cables
during operation.
The motor cable must also be firmly connected to the sequence controller
or the EC servo screwdriver, to ensure a safe contact.
Switch the AST40 sequence controller on using
the main switch (GS1).
6.1.2 Connection side
20
and

Advertisement

Table of Contents
loading

Table of Contents