6.2.7.3

Interface SPS 2

Designation:
Plug connector:
Pin Designation
1
24V
2
24V external
3
Not in use
4
Sequence 5
5
Sequence 6
6
Sequence 7
7
Sequence 8
8
Sequence 5
9
Sequence 6
10
Sequence 7
11
Sequence 8
12
n.c.
13
n.c.
Table 6:
Configuration I/O interface SPS2
CAUTION
Maximum load per output of 50 mA. The total current for all the interfaces
must not exceed 600 mA.
6.2.7.4
Interface 3
Designation:
Plug connector:
Pin Designation
1
Not in use
2
24V Out
3
24V Out
4
24V Out
5
Not in use
6
Not in use
7
n.c.
8
24V Out
Table 7:
Configuration I/O interface 3
CAUTION
Maximum load per output of 50 mA. The total current for all the interfaces
must not exceed 600 mA.
IMPORTANT
24V Out: 24 V DC power supply for the supply of external sensors.
GX3
SUB-D 25-pole (bushing)
Type
-
-
Input
Input
Input
Input
Input
Output
Output
Output
Output
GX4
SUB-D 15-pole (bushing)
Type
Input
-
-
-
Input
Output
-
Pin Designation
14 GND internal
15 GND external
16
n.c.
17
n.c.
18
Sequence 9
19
Sequence 10
20
Sequence 11
21
Sequence 12
22
Sequence 9
23
Sequence 10
24
Sequence 11
25
Sequence 12
Pin Designation
9
Not in use
10 GND external
11 GND external
12 GND external
13
Not in use
14
Reload
15 GND external
16
Type
-
-
Input
Input
Input
Input
Output
Output
Output
Output
Type
Input
-
-
-
Output
Output
-

Advertisement