Panasonic WH-UD05JE5 Service Manual page 97

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-UD05JE5:
Table of Contents

Advertisement

12.4.3 System installation
12.4.3.1
Remote Controller Outline
E
F
2
Name
1: Function icon
2: Mode
3:
Temp setting
4: Display Heat temp
5: Display tank temp
6: Outdoor temp
G
1
12:00am,Mon
24
40 ˚ c
˚ c
18 ˚ c
4
3
Function
Display set function/status
Holiday mode
Weekly timer
Quiet mode
Remote controller room
thermostat
Powerful mode
Display set mode/current status of mode
Heating
Auto
Heat pump operating
Set room temp
Display current heating temperature (it is set temperature when enclosed by line)
Display current tank temperature (it is set temperature when enclosed by line)
Display outdoor temp
Name
A: Main screen
A
B: Menu
C: Triangle (Move)
D: Operate
B
E: Back
F: Quick Menu
C
G: OK
D
5
6
Demand control
Room heater
Tank heater
Solar
Boiler
Cooling
Hot water supply
Compensation
curve
97
Function
Display information
Open/Close main menu
Select or change item
Start/Stop operation
Back to previous item
Open/Close Quick menu
Confirm
Auto heating
Auto cooling
Set direct water
Set pool temp
temp

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-ud03je5Wh-ud07je5Wh-adc0309j3e5ukWh-ud09je5

Table of Contents