Panasonic WH-UD05JE5 Service Manual page 195

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-UD05JE5:
Table of Contents

Advertisement

19.5.6 Abnormal Solar Sensor (H28)
Malfunction Caused:
1
Faulty connector connection.
2
Faulty solar sensor.
3
Faulty indoor sub PCB.
Abnormality Judgment:
Continue for 5 seconds.
Abnormal solar sensor
H28 happens check connection at CN207 normal?
Measure resistance of sensor match characteristic?
Change Indoor sub PCB
YES
YES
For safety reason and to prevent
component breakdown, always switch
Caution
off the power before remove and
connect the component.
NO
Correct sensor connect ion
NO
Change solar sensor
195