3.3

WH-ADC0309J3E5UK WH-UD07JE5

Item
Performance Test Condition
Cooling Capacity
Cooling EER
Heating Capacity
Heating COP
Low Temperature Application (W35)
Application
Pdesign
Tbivalent/TOL
SCOP/ns
Annual Consumption
Class
Medium Temperature Application (W55)
Application
Heating Erp
Pdesign
Tbivalent/TOL
SCOP/ns
Annual Consumption
Class
DHW
Application
COP/nwh
AEC
Noise Level
Air Flow
Refrigeration Control Device
Refrigeration Oil
Refrigerant
GWP
F-GAS
CO
Height
Dimension
Width
Depth
Net Weight
eq (ton) (Precharged/Maximum)
2
Unit
Condition
(Ambient/Water)
kW
BTU/h
kcal/h
W/W
kcal/hW
Condition
(Ambient/Water)
kW
BTU/h
kcal/h
W/W
kcal/hW
Warmer
Climate
kW
°C
2 / 2
(W/W)/%
5.75 / 227
kWh
1627
A++
Warmer
Climate
kW
°C
2 / 2
(W/W)/%
4.07 / 160
kWh
1971
A++
Warmer
Climate
(W/W)/%
3.50 / 140
kWh
714
Condition
A35W7
(Ambient/Water)
dB (A)
Cooling: 49***
Power Level dB
Cooling: 67***
3
3
m
/min (ft
/min)
3
cm
kg (oz)
mm (inch)
mm (inch)
mm (inch)
kg (lbs)
20
Outdoor Unit
EN 14511
EN 14825
A35W7
6.70
22800
5760
3.03
2.61
A7W35
7.00
23900
6020
4.76
4.10
Average
7.0
6.0
-10 / -10
4.90 / 193
2532
A++
Average
6.0
7.0
-7 / -10
3.32 / 130
4354
A++
Average
3.00 / 120
833
A7W35
Heating: 50***
Heating: 68***
Heating: 59****
Cooling: 55.0 (1942)
Heating: 45.3 (1599)
Expansion Valve
FW50S (900)
R32, 1.27 (44.8) (Pre-charged)
R32, 2.27 (80.1) (Maximum)
675
0.857 / 1.532
795 (31-5/16)
875 (34-15/32)
320 (12-5/8)
61 (135)
A2W35
6.85
23400
5890
3.41
2.93
Colder
7.0
-15 / -22
4.18 / 164
4132
A++
Colder
6.0
-15 / -22
2.98 / 116
4967
A+
Colder
2.47 / 99
1013