Item
Liquid
Pipe Diameter
Gas
Standard Length
Pipe Length Range
I/D & O/D Height Difference
Additional Gas Amount
Refrigeration Charge Less
Type
Compressor
Motor Type
Rated Output
Type
Material
Motor Type
Fan
Input Power
Output Power
Fan Speed
Fin material
Fin Type
Heat Exchanger
Row × Stage × FPI
Size (W × H × L)
Power Source (Phase, Voltage, Cycle)
Input Power
Maximum Input Power For Heatpump System
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
Starting Current
Running Current
Maximum Current For Heatpump System
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
Power Cord
Thermostat
Protection Device
(Ambient/Water)
(Ambient/Water)
Number of core
Length
Unit
mm (inch)
mm (inch)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
kW
W
W
rpm
mm
Ø
V
Hz
Condition
A35W7
kW
Cooling: 1.50
kW
A
Condition
A35W7
A
Cooling: 6.8
A
A35W7
%
Cooling: 96
m (ft)
17
Outdoor Unit
6.35 (1/4)
12.70 (1/2)
7 (23.0)
3 (9.8) ~ 25 (82.0)
20 (65.6)
20 (0.2)
10 (32.8)
Hermetic Motor
Brushless (6-poles)
0.90
Propeller Fan
PP
DC (8-poles)
22 (Heating) / 27 (Cooling)
40
Cooling: 980
Heating: 800
Aluminium (Pre Coat)
Corrugated Fin
2 × 28 × 19
36.4 × 588 × 827.7 : 856.3
Single
230
50
A7W35
Heating: 1.00
Heating: 1.32
2.59
1Ø / 12.0 / 2.59k
1Ø / 13.0 / 3.00k
— / — / —
4.7
A7W35
Heating: 4.7
12.0
A7W35
Heating: 93
-
-
Electronic Control
Electronic Control
A2W35
A2W35
Heating: 6.1
A2W35
Heating: 94